ESSENTIALS OF FIRE FIGHTING 7TH EDITION - CHAPTER 3- BUILDING CONSTRUCTION 2024 QUESTIONS WITH CORRECT ANSWERS ALREADY PASSED AND VERIFIED
Type I construction building are considered to be: A. More collapse resistant than other building types B. More likely to suffer structural damage due to the effects of fire C. The most common type of residential construction encountered by firefighters D. Hazardous due to the adhesives and industrial glues used during the construction process - CORRECT ANSWER A. More collapse resistant than other building types Chapter 3 - page 78 Multi-story buildings with flat roofs usually have: A. Cast-in-place concrete roofs B. Roof decking made of corrugated steel C. The same structural system for the roof and the floors D. Different types of structural support systems for every floor - CORRECT ANSWER C. The same structural system for the roof and the floors Chapter 3 - page 95 Which window component is the lowest horizontal member of the frame and supports the window hardware? A. Sill B. Sash C. Jamb D. Glazing - CORRECT ANSWER A. Sill Chapter 3 - page 108 A fusible link on a swinging fire door depends on the heat from a fire to close, so: A. Firefighters should attempt to manually close the fire door when they encounter it B. A significant amount of smoke may flow through the door before the door is released C. The door will close much faster than doors that require a smoke detector to activate the closing mechanism D. The fire door is more easily tested than doors that require a smoke detector to activate the closing mechanism - CORRECT ANSWER B. A significant amount of smoke may flow through the door before the door is released Chapter 3 - page 108 What is one major problem that rain roofs pose for firefighters? A. They pose a significant electrical shock hazard B. They are unable to be penetrated with normal firefighting tools C. They are designed with small open spaces that provide oxygen to the fire D. They create a void that conceals fires and allows them to burn undetected - CORRECT ANSWER They create a void that conceals fires and allows them to burn undetected Chapter 3 - page 100 The lightweight members of a truss assembly are: A. Usually made almost completely of aluminum B. Susceptible to early failure when exposed to fire C. Usually made almost completely of composite plastic D. Able to withstand fire longer than thicker truss components - CORRECT ANSWER B. Susceptible to early failure when exposed to fire Chapter 3 - page 94 Overhead rolling steel fire doors: A. Are often used to protect openings in the required path of egress B. Ordinarily close under the force of gravity when the fusible link melts C. Are unpopular because they use wall space on both sides of the opening D. Function by closing when prompted by an automated closing mechanism - CORRECT ANSWER B. Ordinarily close under the force of gravity when the fusible link melts Chapter 3 - page 106 Which is an accurate statement about fire doors? A. The use of fire doors is restricted to residential occupancies B. The use of fire doors is restricted to commercial occupancies
Escuela, estudio y materia
- Institución
- Rasmussen College
- Grado
- FIREFIGHTER
Información del documento
- Subido en
- 1 de mayo de 2024
- Número de páginas
- 20
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
firefighter
-
type i construct
-
essentials of fire fighting
-
essentials of fire fighting 7th edition
-
fire fighting 7th edition chapter 3
-
chapter 3 building constructio
-
chapter 3 building construction
Documento también disponible en un lote