100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

1 MIC-CT Registry Review-System Operations and Components Questions and Answers 100% Pass

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
23-04-2024
Escrito en
2023/2024

1 MIC-CT Registry Review-System Operations and Components Questions and Answers 100% Pass D - Correct Answer ️️ -The slip ring on continuous rotation CT scanners: a. prevents the high voltage cable from winding up b. allows the exam to commence more rapidly c. eliminates the need for the reversal of gantry frame rotation d. all of the above Analog-to-digital converter - Correct Answer ️️ -Which system component converts the projection attenuation data into the proper digital form for the array processor? Enter the detector chamber, be absorbed by the detector material and be converted to a measureable event - Correct Answer ️️ -In order for an x-ray photon to be measured it must: A - Correct Answer ️️ -Which of the following is NOT a function of a PACS system? A)-Reconstruction of the image from the raw data B)-Long term data storage C)-digital distribution of images D)-image display for the radiologist B - Correct Answer ️️ -Which is NOT part of the CT Tube? a)-tungsten target B)-collimator C)-rotating anode D)-filament D - Correct Answer ️️ -Which of the following is FALSE regarding CT systems? A)-they are limited to non-oblique transverse scanning B)-they cannot generate a straight coronal or Sagittal image C)-they have no moving parts? D) all of the above C - Correct Answer ️️ -X-rays are used in CT because: A) they are easily produced by the high frequency generator B)-they are less harmful than the heating effects of microwave radiation C)-they penetrate the body according to specific attenuation characteristics D)-The FDA imposes no limit on the dose to the patient B - Correct Answer ️️ -Most of the commands from the technologist are received by the: A)-Array processor B)-operators console C)-host computer D)-amplifier B - Correct Answer ️️ -X-Rays are produced whenever fast-moving electrons collide with any form of matter because: A)-the electron splits into two X-ray photons of equal energy upon impact with matter B)-the electron loses kinetic energy which is converted into the emission of an X-ray photon C)-the electron converts the electron it collides with into an X-ray photon A - Correct Answer ️️ -The mA determines: A)-quantity of X-ray photons B)-coefficient of attenuation C) slice thickness D)-energy level of the X-ray photons C - Correct Answer ️️ -Which of the following is a component NOT normally located in the gantry of a modern CT system? A)-pre-patient collimator's B)-solid-state detectors C)-array processor D)-x-Ray tube A - Correct Answer ️️ -Tube inter scan delay time refers to: A)-the time between the end of once scan and the start of the next scan durning which the tube will cool B)-a quality assurance test performed daily by the technologist C)-the time required for the tube to make a complete 360 revolution about the gantry D)-the length of time required for the production of photons to begin after applying the voltage to the tube A - Correct Answer ️️ -Increased ____________ will increase the likelihood that a given X-ray will penetrate a material. A)-kv B)-mA C)-exposure time B - Correct Answer ️️ -Which of the following are NOT commonly used on today's commercially available CT scanners? 1.) Xenon detectors 2.) fourth-generation technology 3.) continuous rotation technology A.) 1 only B.) 1 & 2 C.) 2 & 3 D.) 1,2, & 3 B - Correct Answer ️️ -Which of the following statements is FALSE regarding occurrences after an x-ray photon penetrates the detector aperture? A) the photon can pass through the detector unmeasured B) the photon is converted completely into an electron C.) the measured signal is enhanced by an amplifier C - Correct Answer ️️ -Scatter radiation is caused by: a.) miscalibrated detector b.) x-rays generated spontaneously in the ambient atmostphere c.) deflections from the original trajectory of an x-ray photon through the patient d.) improper patient positioning B - Correct Answer ️️ -What control does the operator have over the x-rays in a CT exam? a.) the temperature and color of the x-rays can be tuned b.) the energy level and the quantity of the x-rays can be selected c.) the volume and tone of the x-rays can be dialed d.) the phase and frequency of the x-rays can be adjusted D - Correct Answer ️️ -Which of the following is the standard that's used to achieve compatibility for image transfer between various imaging modalities, viewing stations, and printers in a hospital? a.) TCP/IP b.) T1 c.) PACS d.) DICOM D - Correct Answer ️️ -The enormous heat that builds up in the CT tube is caused by the: a.) intensity of the x-rays emitted from the tube b.) electron beam between the cathode and the anode in the tube c.) x-ray filter in the tube which absorbs the low

Mostrar más Leer menos
Institución
CT Registry
Grado
CT Registry










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CT Registry
Grado
CT Registry

Información del documento

Subido en
23 de abril de 2024
Número de páginas
18
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmilyCharlene Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
445
Miembro desde
2 año
Número de seguidores
138
Documentos
21009
Última venta
14 horas hace
Charlene\'s Scholastic Emporium.

Your Actual and Virtual Exam Tests Excellent Tutor.

3.7

98 reseñas

5
46
4
13
3
15
2
7
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes