1 MIC-CT Registry Review-System Operations and Components Exam Questions and Answers 100% Correct
1 MIC-CT Registry Review-System Operations and Components Exam Questions and Answers 100% Correct The slip ring on continuous rotation CT scanners: a. prevents the high voltage cable from winding up b. allows the exam to commence more rapidly c. eliminates the need for the reversal of gantry frame rotation d. all of the above - Correct Answer ️️ -D Which system component converts the projection attenuation data into the proper digital form for the array processor? - Correct Answer ️️ -Analog-to-digital converter In order for an x-ray photon to be measured it must: - Correct Answer ️️ -Enter the detector chamber, be absorbed by the detector material and be converted to a measureable event Which of the following is NOT a function of a PACS system? A)-Reconstruction of the image from the raw data B)-Long term data storage C)-digital distribution of images D)-image display for the radiologist - Correct Answer ️️ -A Which is NOT part of the CT Tube? a)-tungsten target B)-collimator C)-rotating anode D)-filament - Correct Answer ️️ -B Which of the following is FALSE regarding CT systems? A)-they are limited to non-oblique transverse scanning B)-they cannot generate a straight coronal or Sagittal image C)-they have no moving parts? D) all of the above - Correct Answer ️️ -D X-rays are used in CT because: A) they are easily produced by the high frequency generator B)-they are less harmful than the heating effects of microwave radiation C)-they penetrate the body according to specific attenuation characteristics D)-The FDA imposes no limit on the dose to the patient - Correct Answer ️️ -C Most of the commands from the technologist are received by the: A)-Array processor B)-operators console C)-host computer D)-amplifier - Correct Answer ️️ -B X-Rays are produced whenever fast-moving electrons collide with any form of matter because: A)-the electron splits into two X-ray photons of equal energy upon impact with matter B)-the electron loses kinetic energy which is converted into the emission of an X-ray photon C)-the electron converts the electron it collides with into an X-ray photon - Correct Answer ️️ -B The mA determines: A)-quantity of X-ray photons B)-coefficient of attenuation C) slice thickness D)-energy level of the X-ray photons - Correct Answer ️️ -A Which of the following is a component NOT normally located in the gantry of a modern CT system? A)-pre-patient collimator's B)-solid-state detectors C)-array processor D)-x-Ray tube - Correct Answer ️️ -C Tube inter scan delay time refers to: A)-the time between the end of once scan and the start of the next scan durning which the tube will cool B)-a quality assurance test performed daily by the technologist C)-the time required for the tube to make a complete 360 revolution about the gantry D)-the length of time required for the production of photons to begin after applying the voltage to the tube - Correct Answer ️️ -A Increased ____________ will increase the likelihood that a given X-ray will penetrate a material. A)-kv B)-mA C)-exposure time - Correct Answer ️️ -A Which of the following are NOT commonly used on today's commercially available CT scanners? 1.) Xenon detectors 2.) fourth-generation technology 3.) continuous rotation technology A.) 1 only B.) 1 & 2 C.) 2 & 3 D.) 1,2, & 3 - Correct Answer ️️ -B Which of the following statements is FALSE regarding occurrences after an x-ray photon penetrates the detector aperture? A) the photon can pass through the detector unmeasured B) the photon is converted completely into an electron C.) the measured signal is enhanced by an amplifier - Correct Answer ️️ -B Scatter radiation is caused by: a.) miscalibrated detector b.) x-rays generated spontaneously in the ambient atmostphere c.) deflections from the original trajectory of an x-ray photon through the patient d.) improper patient positioning - Correct Answer ️️ -C What control does the operator have over the x-rays in a CT exam? a.) the temperature and color of the x-rays can be tuned b.) the energy level and the quantity of the x-rays can be selected c.) the volume and tone of the x-rays can be dialed d.) the phase and frequency of the x-rays can be adjusted - Correct Answer ️️ -B Which of the following is the standard that's used to achieve compatibility for image transfer between various imaging modalities, viewing stations, and printers in a hospital? a.) TCP/IP b.) T1 c.) PACS d.) DICOM - Correct Answer ️️ -D
Escuela, estudio y materia
- Institución
- CT Registry
- Grado
- CT Registry
Información del documento
- Subido en
- 23 de abril de 2024
- Número de páginas
- 17
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
1 mic ct registry review system operations and com
Documento también disponible en un lote