100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

PA-608 Type 2 actual exam 2024 with 100% correct answers(download to pass).

Puntuación
-
Vendido
-
Páginas
3
Grado
A+
Subido en
16-04-2024
Escrito en
2023/2024

Industrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. 35% Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; 30 days Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as; type A- 1 All Refrigeration & HVAC systems are protected by a; pressure relief valve A refrigerant sensor which will sound an alarm and automatically start a ventilation system in occupied equipment rooms fall under; ASHRAE 15 Non-condensables will cause; higher discharge pressure A crankcase heater is often used to prevent refrigerant from migrating to the oil during periods of: low ambient temperature EPA regulations state that maintenance, service or repair involving the removal of the following component is a "major repair" compressor What refrigerant can be used as a trace gas when checking for leaks? R410A What can be done with the refrigerant trace gas and nitrogen after the leak is found? recover in a special tank High pressure appliances can be evacuated to atmospheric pressure (O psig) when There is a leak If a high pressure appliance containing 100 lbs. of an HCFC OTHER THAN R-22 refrigerant Recovery and/or Recycling equipment manufactured after November 15, 1993 must be evacuated to a level of; 10 inches of vacuum When dehydrating a system it should be evacuated to a level of; 500 microns When recovering from a system with a refrigerant leak, recover to a level of; 0 psig When using a recovery system manufactured after November 15, 1993 on a system containing 100 lbs. of R-502 must be evacuated to; 10 inches of mercury If a high pressure appliance containing 210 lbs. of R-22 refrigerant Recovery and/or Recycling equipment manufactured before November 15, 1993 must be evacuated to a level of 4 inches of mercury What conditions allow for a system to be opened and repaired without recovering the refrigerant to the required vacuum level? a system with a large leak and system pressure of atmospheric A new split system should be checked for leaks by; pressurizing the system with a few ounces of R-22 and an inner gas An overcharged system will operate; less efficiently Refrigerant should be removed from the condenser outlet if the condenser is; is below the receiver EPA regulations require that all Commercial and Industrial Process Refrigeration containing more than 50lbs. of refrigerant MUST be repaired when the annual leak rate exceeds; 35% Proper recovery techniques begin with the use of appropriate recovery equipment that has been certified by; EPA approved laboratory

Mostrar más Leer menos
Institución
EPA 608
Grado
EPA 608








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
EPA 608
Grado
EPA 608

Información del documento

Subido en
16 de abril de 2024
Número de páginas
3
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$16.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BRAINBOOSTERS Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
666
Miembro desde
2 año
Número de seguidores
250
Documentos
23197
Última venta
4 días hace

In this page you will find all documents , flashcards and package deals offered by seller BRAINBOOSTERS

4.5

341 reseñas

5
265
4
30
3
21
2
5
1
20

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes