VIVINT SHP PRACTICE EXAM 130QUESTIONS 100%SOLVED
True or false the fire fighter may be installed next to a standalone battery powered smoke detector - False True or false when performing a full system test you may bypass any open doors or windows - False When programming and SKEY1 you must: - Always enable the emergency key True or false when running power to the take-345, polarity does not matter - False Select all that apply when programming the emergency key for SKEY1 one which zone/sensor types are recommended to use - Audible alarm 07 auxiliary alarm 08 True or false when installing a SMKT3 you must use the included screws and anchors - True True or false when installing the fire fighter it is required to test the customers existing smoke detectors - True When installing a DW 21 where is the approved location for the sensor - Between 6 inches (15cm) and 2 inches (61cm) from the floor When installing a DW11 on a vinyl or metal frame what should you primarily use to mount the sensor - Provided double-sided tape Select all that apply which of the following materials can you use to group multiple ground terminals in the takeover module - B connectors/beans and Wire caps Which of the following sensors are not allowed to program using a translator - Smoke detector True or false when installing the take 345 you must always test the new 12 V battery before using it - True What is the output voltage of the transformer used to power the Smart hub - 12 VDC What is the minimum distance for placement of a CO3 from the corners on a wall - 12 inches (30 cm) True or false the SMK3 has only two functions: smoke and heat detection - False How would you program a CO3 if mounted on a hallway wall - Loop 1, zone type 14 When installing a translator you must program all the existing sensors as new equipment on the panel - False When in programming a DW 11 that has been installed on a window which zone/sensor type should be used - 03 True or false the DW 21 sensor should always be installed in the door frame - True When installing a DW 21 into a metal door frame with a wooden door which should you be sure to use? - A DW 11 should be used on all metal door frames Which of the following zone/sensor types are correct when programming a SMKT3 - Type 09 For smoke detection, type 09 for heat detection, type 08 for freeze detection
Escuela, estudio y materia
- Institución
- Vivint SHP
- Grado
- Vivint SHP
Información del documento
- Subido en
- 4 de abril de 2024
- Número de páginas
- 3
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
vivint shp practice exam
-
vivint shp practice exam 130questions 100solved
Documento también disponible en un lote