A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. a. Light b. Medium c. Heavy d. Extra Heavy - Answers c. Heavy From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), and individual other than an individual who is licensed under this article and ______________ working under the direction of a holder of an electrical contractors licence, shall not in any manner undertake to execute any electrical work". - Answers ...And employed by and... A box with (2) 14/3 NM, one yoke, and a clamp requires a minimum or _____ cubic inches. a. 16 b. 18 c. 20 d. 22 - Answers c. 20 NM Cable in a 2x4x2.5 plastic box will not require a cable clamp if secured within _____ inches of the box. a. 8 b. 12 c. 16 d. 20 - Answers a. 8 A box with #10 AWG THHN will require a free space of _____inches. a. 2 b. 2.25 c. 2.5 d. 3 - Answers c. 2.5 (See Table 314.16 (B).) A mobile home with 100 amp service will require service conductors of ____ AWG. a. #4 b. #3 c. #2 d. #1 - Answers a. #4 (See 550.33 (B) and 310.15 (B)(7).) A service with (4) 4" PVC conduits with (4) 800KCMIL feeder in each will require a main bonding jumper of what AWG? a. 4/0 b. 1/0 c. 250 KCMIL d. 500 KCMIL - Answers d. 500 KCMIL (See Table 250.102 (C)(1) and Chapter 9 Table 8 A conduit protecting the grounding electrode conductor shall be bonded to the ____ at both ends. - Answers Grounding Electrode Conductor (See 250.66(E)(1).) A grounding electrode encased in concrete shall be _____ft long and _____ in circumference. a. 8ft, 5/8" b. 12ft, 1⁄2" c. 20ft, 1⁄2" d. Something else... - Answers c. 20ft, 1⁄2" (See 250.52(A)(3).) The required outlet for an in-ground pool shall be mounted _____ a. On the wall of a building 21 feet from waters edge b. On a balcony 8 feet above water level c. On a support 3 feet from waters edge d. On a post 6'6" above grade level - Answers d. On a post 6'6" above grade level (See 680.22(A)(1).) Permanently installed pool motors shall have a cord length of_____ a. 3ft b. 6ft c. 12ft d. 20ft - Answers a. 3ft (See 680.21 (A)(3).) The conductor feeding a wet-niche pool light will be _____ a. Electrical Metallic Conduit b. Rigid conduit made of brass c. Flexible metallic conduit d. Something else..... - Answers b. Rigid conduit made of brass (See 680.23(B)(2) and (B)(2)(a).) Which conductor is not allowed to be used as a service conductor? a. USE b. MC Cable c. Underground Feeder d. MI Cable - Answers c. Underground Feeder (See 338.12 (B) What is the % conduit fill used in a nipple that does not exceed 24" - Answers A: 60% (see chapter 9 table 1 note (4).) Car Wash Receptacle must be - Answers WR Weather Resistant (see 406.9 (B)(1).) Overhead Service conductor clearance for pedestrian walkway - Answers 10' (see 230.24 (B)(1).) Snap switch used for motor must not exceed - Answers 80% of the amp rating of the switch (see 404.14 (A)(3).) Max amperage of Edison based fuse - Answers 30A (see 240.51 (A).) What can you put on a small appliance circuit. - Answers Receptacles for a gas fired range, oven, or countertop cooking unit (see 210.52 (B)(2) Exception 2) Type of branch circuit needed for a furnace or other central heating equipment - Answers Individual Branch Circuit (see 422.12) Receptacle serving AC or refrigeration equipment - Answers Required within 25' (see 210.63) Minimum size hand-hole in a pole supporting a luminaire - Answers 2" X 4" (see 410.30 (B)(1).) Laundry room branch circuit shall be - Answers Dedicated (see210.11 (C)(2).) A receptacle supplying power to a furnace, is required to be powered by what type of electrical circuit. - Answers An INDIVIDUAL circuit What is the required minimum wire size for a ground ring - Answers #2 American Wire Gage (AWG) Why sponsors the NEC - Answers The NEC is sponsored by the NFPA (National Fire Protection Association) The inside of conduit in a wet location is considered to be _____ - Answers Considered to be wet Which term is typically found in the NEC, FLA or FLC - Answers FLC (Full Load Current) What is a coulomb - Answers A quantity (number) of electrons in 1 ampere of current for a deration of 1 second Fuses for overload protection may be used in what type of circuit - Answers 3 wire, 3 phase, 1 conductor grounded What is an electrical JOULE - Answers 1 watt for a period of 1 second Increasing a circuits resistance will do what - Answers Circuit current (amperage) will decrease and circuit power will decrease What is the meaning of "true" or "real" power - Answers True or Real circuit power is the actual power of an electrical system - LISTED IN WATTS What is the meaning of "apparent" power - Answers Apparent power is what the power appears to be - LISTED AS: VA or KVA What motor currents are printed in the NEC: FLA of FLC - Answers FLC (Full Load Current) Ferrous (iron-magnetic) enclosures are connected to a non-continuous ferrous raceway. Raceways must be bonded to electrical enclosures - HOW - Answers Raceways must be electrically bonded through and at each end of a non-continuous raceway to the enclosures(s) Electrons move in which direction - Answers Negative (-) to Positive (+) A non-grounding receptacle is replaced with a grounding receptacle. What must be done to comply with MRC - Answers Option 1 - The replaced receptacle must be labeled "no equipment ground" Option 2 -If supplied thru a GFCI, the replaced receptacle must be labeled "GFCI protected" and "no equipment ground" *this may be "both A and C" type of question* What makes electrocs move in a conductor - Answers EMF, voltage, and potential *this may be an "all of the above" or "A, B, and C" type of question* The "Left Hand Rule" is commonly used to determine - Answers Used to indicate the path of electrical current and the direction of a circuits magnetic north Electrical current in a conductor creates what around the conductor - Answers A magnetic flux field Three resistors are connected in series. How is the total resistance calculated - Answers The resistors are added together "Voltage Drop" is equal to what formula (from the EIR circle) - Answers E (voltage drop) = I (current) x R (resistance) Conduit threads cut in the field must be coated with a compound that is - Answers Electrically conductive and non-corrosive Can a Master Electrician pull an electrical permit - Answers No What does the winding ratio of a transformer refer to - Answers The number (ratio) of primary windings compared to the number (ratio) of secondary windings What is the most common purpose of using a transformer - Answers To change voltage To use flexible metallic conduit as a grounding means, what is required - Answers Cossin doesn't really answer this. It could be any of the following, are a combination. • The conduit is terminated in listed fittings • The circuit conductors in the conduit are protected by an OCPD rated 20A or less • The size of the conduit does not exceed metric designator 35 (trade size 1 1⁄4") • The length of the ground-fault current path does not exceed 1.8 m (6')


Información del documento

Subido en
7 de febrero de 2024
Número de páginas
19
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Exampool
3.9
(32)
Vendido
224
Seguidores
148
Artículos
3589
Última venta
12 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.