100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Backflow Exam Questions With Answers Latest Updated 2024 (Graded A+)

Puntuación
-
Vendido
-
Páginas
15
Grado
A+
Subido en
09-01-2024
Escrito en
2023/2024

Backflow Exam Questions With Answers Latest Updated 2024 (Graded A+) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: C. Public water system or consumer's portable water system 2) An approved airgap (AG) is a physical separation between the free-flowing end of a: D. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 3) And indirect cross-connection is one that is subject to what type of backflow? A. Only backsiphonage 4 )Cross-connections with between the portable water piping in any piping or containers containing substances not approved as potable water must be either eliminated or controlled by the installation of an: D. Approved air gap or an approved backflow prevention assembly 5) While testing CV #2 of a DCVA if CV #2 leaks the BAT would observe that the water flow: D. Stops from the site tube at TC#4 and no differential shows on the gauge 6) Service protection is a way to protect a public water system from contamination due to back flow from the customer's water system by the installing an approved backflow preventer at the: A. Service connection which is considered to be at or near the water meter 7) A Washington state certified Backflow Assembly Tester is certified to: D. Inspect, test and monitor backflow prevention assemblies 8) The RPBA is designed so that if the check valve leaks, the relief with valve may: B. Open to discharge through the relief valve vent 9) An AG installed in lieu of an approved backflow prevention assembly must be inspected for compliance with the definition of an improved air gap by: C. Either a CCS or a BAT 10) After testing an approved backflow prevention assembly the BAT shall complete a test report that is acceptable to the: C. Purveyor 11) The gauge on a differential pressure test kit indicates: C. psid 12) Loading a check valve with springs or weights: C. Reduces pressure down stream of the check valve 13) If there is flow across CV#1 and through an RPBA the relief valve will not discharge unless: C. The relief valve is defective 14) Microbiological contaminates entering the portible water system are always a: A. Highhealth standard 15) All approved backflow prevention assemblies must be tested with a: D. Differential pressure test kit 16) An approved backflow prevention assembly is an: C. RPBA, RPDA, DCVA, DCDA, PVBA, or SVBA of make, model, and size that is approved by the DOH 17) Permanent support blocks are required under all approved backflow assemblies that are: D. A large size assembly 18) A backflow assembly test report must be: C. Complete, accurate and legible 19) SOV #1 of a properly installed PVBA is reported as leaking while testing the air inlet valve if water continues to flow from: C. The high-bleed valve and the differential gauge does not drop to the opening point of the Air Inlet Valve

Mostrar más Leer menos
Institución
Backflow
Grado
Backflow









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Backflow
Grado
Backflow

Información del documento

Subido en
9 de enero de 2024
Número de páginas
15
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUDYROOM2024 Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
397
Miembro desde
2 año
Número de seguidores
212
Documentos
3947
Última venta
4 semanas hace

For all Nursing Test Banks visit my page. All Papers are Verified and Graded to Score A++ Wish you Success.

3.5

59 reseñas

5
19
4
14
3
13
2
4
1
9

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes