EPA 608 Type 1 Questions and Answers 100% Pass
EPA 608 Type 1 Questions and Answers 100% Pass Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after - Answer ️️ -November 15, 1993 Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: - Answer ️️ -recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under conditions of ARI 740-1993 EPA's definition of a small appliance includes: - Answer ️️ -a device manufactored, charges & hermeticly sealed in factory with a charge of 5lbs or less Tech's with a type 1 small appliance certification are certified to recover refrigerant during the maintenance or repair of: - Answer ️️ -PTAC's with 5lbs or less of refrigerant EPA requires that all small appliances be equipped with a service aperture or other device that is used when adding or removing refrigerant from the appliance. For small appliances this service port typically - Answer ️️ -a straight piece of tubing, called a process tube that is entered using a piercing valve The EPA section 608 certification must be renewed every - Answer ️️ -never It is an EPS regulation that any person who opens and appliance for maintenance, service or repair must have at least one self-contained recovery machine avalible at their place of buisiness. The only exception to this rule are persons working on - Answer ️️ -small appliances The sale od CFC & HCFC refrigerants is: - Answer ️️ -restricted to techs who are EPA certified in refrigerant recovery Anyone who recovers refrigeration during maintenance, service or repair of small appliances must be certified as either a universal Tech or a: - Answer ️️ -Type 1 tech When recovering refrigerant from a household refrigerator who's compressor does not run, it is recommended that a low and high side access valves be installed because: - Answer ️️ -it can help speed of recovery and required recovery effiency If you install an access fitting into a sealed system: - Answer ️️ -the fitting should be leak tested before proceeding with recovery
Escuela, estudio y materia
- Institución
- EPA 608
- Grado
- EPA 608
Información del documento
- Subido en
- 8 de enero de 2024
- Número de páginas
- 3
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
epa 608 type 1 questions and answers 100 pass
Documento también disponible en un lote