BECC Mod 4 Review Exam Questions and answers. Verified. The Fireman System originates below the waterline with the __________. - -Sea Chest Which valve is the last valve you open before putting the pump on line and the first valve you will shut when securing the pump? - -Fire Pump Discharge Valve What valves are used to isolate system components? - -Cutout, Discharge, and Cross Connect Valves Gate, Ball, Globe (Pump Discharge), or High Performance butterfly valves are considered ________________. - -Cutout Valves For which monitoring method must the assigned watchstander notify DCC that the fire pump is aligned for operation? - -Local Secondary, or alternate fireman monitoring is conducted from the Damage Control Deck, or under emergency conditions at the _________. - -Pump Which methods are used to control fire pump or firemain valve operations? - -Remote, Local, and Automatic Relief valves protect the fireman system from over-pressurization by relieving pressure at approximately _____ PSIG above the firemain design pressure. - -50 Where is a coupling guard installed on the fire pump? - -Over the rotating shaft Which pipe runs fore-to-aft of the ship and carries the firemain water? - -Mai