100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

IRC Plumbing Practice Test Questions And Answers All Verified A+ Graded

Puntuación
-
Vendido
-
Páginas
42
Grado
A+
Subido en
08-12-2023
Escrito en
2023/2024

IRC Plumbing Practice Test Questions And Answers All Verified A+ Graded What is the minimum size of a water meter and service piping in inches for a water supply system of 34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35 psi. - ANS 1 Table AP201.1 What is the minimum sized trap that can be used for the drainage system of a bathtub (with or without shower head and/or whirlpool attachments)? - ANS 1.5 Table P3201.7 A water heater pan drain must extend full-size and terminate over a suitably located indirect waste receptor or must extend to the exterior of the building and terminate not less than _____ inches and not more than _____ inches above the adjacent ground surface. - ANS 6, 24 P2801.6.2 A laundry tray waste line is permitted to connect into a standpipe for automatic clothes washer drain. The standpipe must extend not less than _____ above the trap weir and must extend above the flood level rim of the laundry tray. - ANS 30 inches (762 mm) P2706.1.2.1 Clothes closets, linen closets and pantries not exceeding _____ in area, with the smallest dimension not greater than 3 feet (915 mm) and having wall and ceiling surfaces of gypsum board will not require fire sprinklers. - ANS 24 square feet (2.2 m2) P2904.1.1 If a water closet can be removed to provide cleanout access, does that fulfill the cleanout requirement of the code? - ANS No P3005.2.3 Appliances and equipment used for heating water or storing hot water have to be protected by _____. - ANS pressure-relief valve and temperature-relief valve or a combination pressure and temperature-relief valve. P2804.1 Where the fixture drains connect at different levels, the common vent must connect as a _____ extension of the _____ drain. - ANS vertical, vertical P3107.3 The minimum air gap distance in inches for lavatories and other fixtures with effective opening not greater than 1/2 inch in diameter that are close to a wall is: - ANS 1.5 Table P2902.3.1 In areas prone to flooding as established by the code, water supply systems must be designed and constructed to prevent _____ of floodwaters. - ANS infiltration P2602.2 When either a public water-supply or sewer system, or both, are not available, _____, an individual water-supply or individual sewage-disposal system, or both, must be provided. - ANS or connection thereto is not feasible P2602.1 _____ installed in a bathroom are not required to be installed within an enclosure. - ANS direct-vent water heaters M2005.2 For water supply systems used predominantly for flush tanks having a water supply fixture unit load of 12, what is the comparable demand in gallons per minute. - ANS 16.0 Table P2903.6(1) Test equipment, materials and labor must be furnished by the ______ - ANS permittee P2503.3

Mostrar más Leer menos
Institución
IRC Plumbing
Grado
IRC Plumbing











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
IRC Plumbing
Grado
IRC Plumbing

Información del documento

Subido en
8 de diciembre de 2023
Número de páginas
42
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyclock Ashford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
851
Miembro desde
3 año
Número de seguidores
492
Documentos
8831
Última venta
4 horas hace

4.2

223 reseñas

5
131
4
36
3
34
2
10
1
12

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes