ABSA 4b Exam Latest Version. Warm Air Heating System Equipment In a warm air heating system the cold air return registers are located a) in exterior walls b) in interior locations c) under windows d) in floors e) in ceilings B The major disadvantage of an electric resistance coil furnace for warm air heating is a) the high cost of electricity b) the danger from electric shock c) the high cost of maintenance d) the large size of the furnace e) the location of electrical wiring A Lowboy furnaces are just over a) 1.0 m in height b) 0.8 m in height c) 1.4 m in height d) 1.6 m in height e) 1.2 m in height E The advantage of having duct furnaces instead of a large central furnace is a) less initial cost b) easier installation c) better con

Mostrar más Leer menos
Institución
Grado











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Grado

Información del documento

Subido en
3 de diciembre de 2023
Número de páginas
134
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ABSA 4b Exam Latest Version.
Warm Air Heating System Equipment
In a warm air heating system the cold air return registers
are located
a) in exterior walls
b) in interior locations
c) under windows
d) in floors
e) in ceilings
B
The major disadvantage of an electric resistance coil furnace
for warm air heating is
a) the high cost of electricity
b) the danger from electric shock
c) the high cost of maintenance
d) the large size of the furnace
e) the location of electrical wiring
A
Lowboy furnaces are just over
a) 1.0 m in height
b) 0.8 m in height
c) 1.4 m in height
d) 1.6 m in height
e) 1.2 m in height
E
The advantage of having duct furnaces instead of a large
central furnace is
a) less initial cost
b) easier installation
c) better control of heat in each zone of the building
d) that they require less space
e) lower maintenance costs
C
The power supply for an electric resistance coil furnace is
a) 60 V
b) 120 V
c) 240 V
d) 220 V
e) 480 V
C
In a fin-coil heat exchanger the primary source of heat for
the exchanger is
a) steam or hot water
b) gas
c) oil

,d) solar
e) radiant
A
A type of directly fired space heater is
a) a unit heater
b) a floor furnace
c) a wall furnace
d) all of the above
e) none of the above
D
High efficiency furnaces and heaters range in annual fuel
utilization efficiency (AFUE) from
a) 94 - 98%
b) 80 - 95%
c) 70 - 75%
d) 60 - 70%
e) 50 - 60%
B
In high efficiency furnaces if the temperature of the flue
gas drops below 65 degrees C the
a) flue gas will condense
b) water vapour will condense
c) furnace burner will shut down
d) furnace burner will start up
e) furnace vent will close
B
In a pulse combination furnace the stated efficiency is
a) 94 - 98%
b) 80 - 95%
c) 70 - 75%
d) 60 - 70%
e) 50 - 60%
Warm Air Furnace Components and Maintenance
A
Heat exchangers in gas fired furnaces are made of
a) brass
b) copper
c) aluminum
d) steel
e) cast iron
D
Air filters can be divided into two groups
a) mechanical and rotating drum
b) electronic and steam
c) dry and wet

,d) steam and rotating drum
e) mechanical and electronic
E
Electronic filters will remove
a) all particles from the air
b) fine particles from the air
c) odour producing gases from the air
d) smoke from the air
e) all of the above
B
The perimeter loop system of furnace ducting is ideal for a
building with
a) no insulation in the walls
b) concrete walls
c) no basement
d) low head room in the basement
e) no cold air returns
C
Which of the following is a type of outlet in a warm air
heating system?
a) a grill
b) a register
c) a ceiling diffuser
d) a perforated panel
e) all of the above
E
Supply outlets should always be located
a) in walls
b) in floors
c) in ceilings
d) to best prevent cold drafts
e) in baseboards
D
In a warm air heating system, the heated air should enter the
rooms preferably via the
a) high wall registers on the inside wall
b) baseboard registers on the inside wall
c) baseboard registers on the outside wall
d) high wall registers on the outside wall
e) unit heaters on the outside wall
C
Sleeve bearings on furnace fans require
a) no lubrication
b) grease every six months
c) a few drops of oil every six months

, d) a few drops of oil monthly
e) flood lubrication
C
Furnace heat exchangers should be checked for corrosion
because
a) carbon monoxide could leak into the building
b) the holes reduce the furnace efficiency
c) cold air could leak into the building
d) too much air would enter the furnace
e) the air will become too dry for comfortable heating
A
Insufficient heat throughout a building is likely caused by
a) too high an air flow
b) insufficient heat input
c) poorly insulated ducting
d) a missing filter
e) poor humidity control
B
Rooms that are stuffy and dry are created by
a) poor air distribution
b) a low supply air temperature
c) too much ventilation air
d) poorly insulated ducts
e) none of the above
Ventilation and Air Filters
E
Actual ventilation rates may vary per person from
a) 0.5 to 0.6 cubic metres/min
b) 0.5 to 0.75 cubic metres/min
c) 0.2 to 1.2 cubic metres/min
d) 0.14 to 1.5 cubic metres/min
e) 1.0 to 1.5 cubic metres/min
D
Ventilation can be divided into two basic methods:
a) forced and natural
b) mechanical and natural
c) forced and mechanical
d) natural and warmed air
e) natural and cold air
B
Natural ventilation is improved by the use of a roof
a) ventilator
b) radiator
c) grille
d) louver
e) panel
$25.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ACADEMICAIDSTORE Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1199
Miembro desde
4 año
Número de seguidores
890
Documentos
11616
Última venta
2 días hace
ACADEMICAID STORE

Welcome to ACADEMICAID store! We specialize in reliable test banks, exam questions with verified answers, practice exams, study guides, and complete exam review materials to help students pass on the first try. Our uploads support Nursing programs, professional certifications, business courses, accounting classes, and college-level exams. All documents are well-organized, accurate, exam-focused, and easy to follow, making them ideal for quizzes, midterms, finals, ATI & HESI prep, NCLEX-style practice, certification exams, and last-minute reviews. If you’re looking for trusted test banks, comprehensive exam prep, and time-saving study resources, you’re in the right place.

Lee mas Leer menos
4.1

173 reseñas

5
95
4
29
3
28
2
6
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes