100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NYC MASTER ELECTRICIAN EXAM (2023/2024) RATED A

Puntuación
-
Vendido
-
Páginas
41
Grado
A+
Subido en
18-11-2023
Escrito en
2023/2024

NYC MASTER ELECTRICIAN EXAM (2023/2024) RATED A Type ____ is multiconductor cable identified for use as underground service entrance cable. Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. 30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? 4% Which of the following statements best describe the grounding requirement for central vacuum outlet Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature 3 inches Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. 6 ft Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed Green finish Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating Hexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? 5000 watts Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. 3 ft (36 inches) —— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. Class H Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F 3" inches The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. 8 In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? Combination range hood/microwave oven Type 3 Surge Protective devices can be installed on the load side

Mostrar más Leer menos
Institución
NYC MASTER ELECTRICIAN
Grado
NYC MASTER ELECTRICIAN











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NYC MASTER ELECTRICIAN
Grado
NYC MASTER ELECTRICIAN

Información del documento

Subido en
18 de noviembre de 2023
Número de páginas
41
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
StellarScores Western Governers University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1907
Miembro desde
2 año
Número de seguidores
864
Documentos
21100
Última venta
11 horas hace
Your Academic Hub: Documents, Study Guides, Summaries, Essays, and Exclusive Package Deals.

Welcome to my comprehensive academic resource store! At my online hub, I offer a vast array of meticulously crafted documents, study guides, summaries, and essays to support your educational journey. I understand the value of accuracy and completeness, which is why all my materials are verified and kept up-to-date with the latest versions. But that's not all! I also offer exclusive package deals and bundles to provide you with cost-effective solutions for your academic needs. Whether you're a student looking for study aids or seeking in-depth knowledge, my store is your one-stop destination for reliable, top-quality materials that can propel your learning experience to new heights. Explore my offerings and unlock the keys to academic success today!

Lee mas Leer menos
4.0

439 reseñas

5
238
4
78
3
61
2
24
1
38

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes