ug/g - ANSWERSmicrogram per gram ug/ft2 - ANSWERSmicrogram per foot square (dust sampling) mg/cm2 - ANSWERSmilligrams per centimeter squared (XRF) ug/dL - ANSWERSmicrogram per deci-liter ug/m3 - ANSWERSmicrogram per deci-liter (quantity in blood) 1% - ANSWERS10,000 ppm Allowed quantity of lead in dry surface paint when testing with XRF. - ANSWERS1.0 mg/cm2 Allowed quantity of lead in dry surface paint when testing with paint chip - ANSWERS5000 ppm Allowed quantity of lead in dry surface paint by weight - ANSWERS.5% = 5000ppm Lead Quantities for Dust Clearance from floors/carpet - ANSWERS40 ug/ft2 Lead Quantities for Dust Clearance from furniture - ANSWERS40 ug/ft2 Lead Quantities for Dust Clearance from window sills - ANSWERS250 ug/ft2 Lead Quantities for Dust Clearance from w