100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NCLE Test Questions & Answers Solved 100%

Puntuación
-
Vendido
-
Páginas
26
Grado
A+
Subido en
30-10-2023
Escrito en
2023/2024

Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is achieved by the use of the- a. profile analyzer b. shadow graph c. keratometer d. burton light - Answer a. profile analyzer Contact lens power should be specified in- a. back vertex power b. sphero-cylinder power c. power in situ d. posterier apical radius - Answer a. back vertex power The slit-lamp illumination that gives an overall view of the cornea but limits detail is- a. sclerotic scatter b. diffuse c. specular reflection d. oscilatory - Answer b. diffuse When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit is too- a. small b. large c. steep d. flat - Answer c. steep Transient keratometric mier distortion is usually due to- a. pre-ocular tear film abnormalities b. prolonged rigid lens wear c. prolonged soft lens wear d. irregular corneal astigmatism - Answer a. pre-ocular tear film abnormalities Epithelial edema which manifests itself clinically as central corneal haze, is verified by the slit lamp using sclerotic scatter illumination. What specific technique does the examiner use to see this condition? a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ b. the blue cobalt filter of the slit lamp and an angle of about 45˚ c. the green filter of the slit lamp with high magnification d. high magnification and an angle between the beam and scope of 180˚ - Answer a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally wih a concentration of flourescein inferiorly and superiorly under the lens. Which one of the following type of astigmatism is represented by this pattern? a. lenticular astigmatism b. residual astigmatism c. against the rule astigmatism d. with the rule astigmatism - Answer d. with the rule astigmatism Refractive Rx -3.00 -1.00 x 170 K's 42.00 @ 170/43.00 @ 80 Given the above Rx and K's he following diagnostic toric soft lens was used: B.C. 8.8 Power -3.00 -1.00 x 180 During dianostic evalutation, the above lens rotated 10 clockwise. The lens ordered should have an axis of: a. 10 b. 180 c. 170 d. 160 - Answer b. 180 Given the same circumstances from the above question, once the correctly ordered lens has been dispensed, the rotational marks should settle at _______. a. 6 o clock b. 10 clockwise rotation c. 10 counter clockwise rotation d. none of the above - Answer b. 10 clockwise rotation An instrument that allows simultaneous verification of lens diameter, optic zone width, and peripheral curve width is: a. measuring magnifier b. ophthalmometer c. profile analyzer d. radiuscope - Answer a. measuring magnifier (the book says d. radiuscope) The instrument used for magnification of the edge of a rigid CL is a _______. a. radiuscope b. shadowgraph c. profile analysis d. keratometer - Answer b. shadowgraph Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power of +2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her a new lens with a curve of 43.00, what will the new power be? a. +1.50 b. +2.00 c. +2.50 d. +3.00 - Answer c. +250 Which of the following could be considered in the fitting of a keratoconus patient 1. aspheric 2. McGuire 3. Soper 4. tangent streak a. 1 & 2 b. 2 & 3 c. 3 & 4 d. 1, 2 and 3 - Answer d. 1, 2 and 3 Two designs helpful in orienting high riding myopic lenses are: 1. flattening the B.C. relationship 2. myo-flang 3. hyper-flang 4. prism ballast a. 1 & 2 b. 1 & 3 c. 2 & 3 d. 3 & 4 - Answer d. 3 & 4 Age/related signs of presbyopia include: 1. tear film abnormalities 2. reduce lid elasticity 3. lens opacities 4. pupil constriction a. 1 only b. 1 & 3 c. 2 & 4 d. all of the above - Answer d. all of the above A good example of a bifocal contact lens which may rotate without vision imparement is: a. aspheric b. executive c. fused crescent d. tangent streak - Answer d. tangent streak Keratoconus and penetrating keratoplasty fittings are best accomplished by which of the following methods? a. nomogram b. Ks and Rx c. diagnostic fitting d. molded impression - Answer c. diagnostic fitting Given the following information: K's 45.00/44.00 @ 90 Rx -3.00 + 1.00 x 180 Which of the following set of lens specifications would most simulate an intrapalpebral RGP fitting? B.C Rx Dia. a. 44.50 -2.50 8.5 b. 43.50 -1.50 8.5 c. 43.50 -1.50 9.5 d. 44.50 -2.50 9.5 - Answer B.C Rx Dia. a. 44.50 -2.50 8.5 (NUMBER 22) Given the following information: K's 45.00 @ 180/42.00 @ 90 Rx -2.00 -4.25 x 90 Which of the following RGP lens designs would best correct this wearers vision? a. 45.00 -2.00 b. 42.00 -2.00 -4.25 x 90 prism ballasted c. 42.00 -2.00 d. 42.00/45.00 -2.00 - Answer d. 42.00/45.00 -2.00 A _________ lens is a translating bifocal: a. concentric b. aspheric c. deffractive d. segmented - Answer d. segmented Given the following information: K's 42.50@180/42.50@90 Rx -3.00-1.00@90 Which of the following set of RGP lens specifications will best correct this wearers vision? a. 42.50/43.50 -3.00-1.00x90 b. 42.50 -3.00-1.00x90 prism ballasted c. 42.50 -3.00 d. 43.00 -3.50 - Answer b. 42.50 -3.00-1.00x90 prism ballasted Given the following information: K's 42.00@180/45.00@90 Rx -3.00-2.25x180 Which of the following set of RGP lens specifications will best correct this wearers vision? a. 42.00/45.00 -3.00-2.25 b. 42.00 -3.00-2.75 x 177 prism ballasted c. 42.00 -3.00 d. 45.00 -3.00 - Answer a. 42.00/45.00 -3.00-2.25

Mostrar más Leer menos
Institución
NCLE
Grado
NCLE










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NCLE
Grado
NCLE

Información del documento

Subido en
30 de octubre de 2023
Número de páginas
26
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Exampool NURSING
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
219
Miembro desde
2 año
Número de seguidores
147
Documentos
3591
Última venta
1 mes hace
Power-horse Library

HELLO Dear ones On this Account you will find all Study related Materials ,EXAMS, STUDY GUIDES, CASES,NOTEBOOKS and many more. well come as we study for Excellency.

3.9

32 reseñas

5
16
4
2
3
10
2
2
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes