CSFSM S-56 EXAM| 74 QUESTIONS WITH COMPLETE VERIFIED SOLUTIONS|GUARANTEED SUCCESS
F-01 COF for impairment F-60 COF for fire guard for torch operation and construction site G-60 Torch operation P-54 Crane serial fueling operation at construction site S-92 Supervision of portable fueled space heaters S-93 Supervising temporary storage and dispensing flammable or combustible liquids E-21 Using powder activated tools A-49 Supervision of aerosals G-40 Use of LPG CNG for tar kettles, asphalt melter and marking street line G-44 Storage and handling of LPG CNG Pre-Fire Plan Shall develop and maintain an approved plan. Fdny shall be notified of any changes at the jobsite affecting the plan Fire drills Held every quarter with recorded results Training Review with Employees the use of a portable fire extinguisher and perform every 6 months. Topics of pre fire plan Site safety, fire protection, and tenant protection, daily log, responder box Structures undergoing demo Standpipes shall be maintained as a dry Standpipe system with air pressurized alarm. Structure Height greater then 75 ft Standpipe shall contain air pressurized alarm system Weekly Spot checks & visual insp. Perform on Standpipes and gauges of the alarm system Licensed plumber or master fire suppression Conduct air pressure hydrostatic test on all new Standpipe alarms ANSI A13.1 Standpipes painted red or ID by lettered legend. OS&Y Shall be locked by chain in the open position Combo standpipe Valve handles marked yellow Steps for Impairment of Standpipe Cease all work, call FDNY, conduct pre-fire plan, contact super, confirm headcount, call plumber, call FDNY with corrections, master fire suppression contractor and note all on daily log. FC 1415.1 Fire Code for Fire Extinguishers 2A 20: BC minimum fire extinguisher rating on the jobsite 75 ft & 1,500 sq. ft maximum travel distance for fire extinguishers or area of room multi-floor structures or wood scaffold 40+ ft at least one extinguisher placed near each stair 40-B:C rating for wheeled fire extinguisher. Kept within 30 ft from flammable liquid storage cage. 2-A rating at least 1 fire extinguisher next to each small ammunition storage area 1 per 1,000 sq. ft fire extinguisher required with operational coke salamander temporary heat. Max travel distance is 75 ft. LPG heaters during temp. heating at least 1 extinguisher within 30 feet of heating SCF standard cubic feed 400 SCF FDNY permits required when storing, handling, using flammable gases Permanent permit valid for 12 months only. Temporary permit valid for 1 day up to 12 months depending on construction needs. Typical for construction job. Citywide permit normally issued when hot work operations are anticipated to be completed in 30 days or less 3,500 SCF Indoor storage of flammable gas shall not be more than this amount per control area. Two 3,500 SCF cages shall be separated by 50 feet. combustible materials during hot work all of these types of materials shall be more than 35 ft away from the operation or shielded / protected. After hours fire guard Required when jobsite exceeds 10,000 sq. ft fronting one street or 20,000 when fronting two streets or whenever it exceeds 75 ft in height. substantial fence around jobsite increased area limitations for fire guard per 15,000 sq. ft fronting one street or 30,000 when fronting two. Offshift hours 4pm - 12pm fire guard is required when work is not in process F-60 / F-93 / F-30 Fire guard shall have these COF's along with OSHA 10hr Watchperson required from midnight-8AM when building/jobsite occupies area of more than 5,000 sq. ft up to 40,000 sq. ft. If the area is greater than 40,000 sq. ft, additional watchperson required. NO COF Required, but must have OSHA 10hr 15 cubic yards This amount of combustible material must be removed daily before end of day. 25 gallons of flammable liquids Max limit for storing flammable liquids outside approved storage. 60 minutes or more When hot work has stopped for more than 60 minutes torch valve and gas supply needs to be closed-circuit. 15,000 SCF The max storage quantity for flammable gases in any building or structure
Escuela, estudio y materia
- Institución
- 123 University
- Grado
- FDNY
Información del documento
- Subido en
- 25 de octubre de 2023
- Número de páginas
- 7
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
csfsm s 56 exam
Documento también disponible en un lote