100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NYC FSD TEST| 191 QUESTIONS AND ANSWERS|GUARANTEED SUCCESS

Puntuación
-
Vendido
-
Páginas
78
Grado
A+
Subido en
25-10-2023
Escrito en
2023/2024

Impairment Coordinator Person responsible for ensuring the proper safety precautions are taken when the protection system is placed out of service (designated by the owner). How many feet of hose would be found at the standpipe outlet ? 125 feet In fire prevention there are three areas to consider: Education (building tenants) Engineering (layout, suppression systems etc) Enforcement(Building codes, Fire codes) Fire Drill Frequency for Group B Twice a year Fire Drill Frequency for Group R1 Quarterly each year Refresher training for Group B 1 hour annually (training) Refresher Training for Group R1 1 hour quarterly on each shift The fire alarm system on your buildings 4th floor has stop functioning. In this case, the fire alarm system would be deemed: out-of-service It shall be unlawful to transmit unnecessary or unwarranted alarms in any six-month period if the amount of those alarms is: three or more Which of the following statements is accurate ? A. Activation of a manual pull box shall not be construed as an unnecessary alarm. B. Activation of a manual pull box shall not be construed as an unwarranted alarm. C. Activation of a manual pull box shall not be construed as an unattended alarm. D. Activation of a manual pull box shall not be construed as a disfunctional alarm. A. Activation of a manual pull box shall not be construed as an unnecessary alarm. 5. The fire alarm system on the15th floor is unable to function in conformance with the law. In this case, the FSD should promptly notify: A. the tenants occupying the 15th and 16th floors B. the tenants occupying the 15th, 16th and 17th floors C. the tenants occupying the 15th and 14th floors D. the tenants occupying the 15th floor D. the tenants occupying the 15th floor (occupants of the affected area). 6. An alarm log book shall be maintained on the premises. In general, where should it be kept ? A. in the Property Managers Office B. in the Chief Engineers Office C. in the Mechanical Equipment Room D. at the fire command station D. at the fire command station 7. Which of the following statements about the Alarm Log Book is incorrect? A. shall be a bound book (other than spiral bound) B. all entries shall be made in ink and dated C. shall be retained for a period of two years from the date of the last entry D. separate log book shall be kept for each calendar year C. shall be retained for a period of two years from the date of the last entry - 3 years not 2. 8. The interior fire alarm pull stations are positioned at the natural exits on each floor of the building. In larger buildings the fire alarm pull stations must be spaced so that the distance between stations does not exceed A. 200 feet B. 150 feet C. 300 feet D. 100 feet A. 200 feet 9. Interior fire alarm pull stations must be securely mounted to the wall A. at eye level B. between 3.5 and 5 feet above the floor level C. between 3 and 6 feet above the floor level D. at various heights depending on the tenancy B. between 3.5 and 5 feet above the floor level 10. All fire alarm pull stations must be painted . A. red with white stripes B. white with red stripes C. red D. white with red lettering C. red 11. Once activated, a fire alarm system cannot be shut off at the pull station. The alarm must be shut off at the main control panel by which of the following people? A. only the Certificate of Fitness holder B. only a uniformed member of the NYFD C. the Certificate of Fitness holder or a member of the engineering staff D. the Certificate of Fitness holder or an FDNY representative D. the Certificate of Fitness holder or an FDNY representative 12. In the case of a fire emergency where building occupants must be evacuated, occupants on which floor(s) are most seriously threatened by the spread of the fire and must be evacuated first? A. the fire floor and the floor above B. the fire floor and all floors above it C. the fire floor, the floor above it, and the floor below it D. the fire floor and other floors as determined by the FSD B. the fire floor and all floors above it 13. When a fire alarm pull station located outside your office building is used, the person who pulled the alarm must A. report to the Fire Command Station immediately afterwards B. notify his/her immediate supervisor C. wait at the alarm station until the fire fighting units arrive D. do nothing after pulling the alarm C. wait at the alarm station until the fire fighting units arrive 14. An alarm triggered by smoke from a lit cigarette in a non-smoking area, when the presence of such smoke does not implicate fire safety concerns, is called A. an unwarranted alarm B. an unnecessary alarm C. an unfounded alarm D. an unsubstantiated alarm B. an unnecessary alarm 15. An alarm signal transmitted by a fire alarm system which failed to function as designed is considered to be an unwarranted alarm. This type of alarm comes about as a result of A. improper installation B. improper maintenance C. malfunction D. all of the above D. all of the above 16. A signaling system which is operated by, and whose signals are received by the owner of the protected premises and which signals are capable of transmitting information to a Fire Department Borough Communications Office, is called A. an ancillary protective signaling system B. a proprietary protective signaling system C. a sub-system protective signaling system D. a direct-call protective signaling system B. a proprietary protective signaling system 17. During fire emergencies, the primary responsibility of the Fire Safety Director shall be A. the supervision and manning of the Fire Command Station B. the supervision and overseeing of fire fighting activities C. the supervision and overseeing of sprinkler/standpipe activation D. the supervision and manning of the search and rescue operation A. the supervision and manning of the Fire Command Station 18. In buildings100 feet or more in height, the Fire Command Station communication system shall be located on the ground floor and be able to communicate with all of the following locations except A the building roof B. each floor of the building C. the elevator control room D. the mechanical equipment room A the building roof

Mostrar más Leer menos
Institución
Grado











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Grado

Información del documento

Subido en
25 de octubre de 2023
Número de páginas
78
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GUARANTEEDSUCCESS Aalborg university
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
649
Miembro desde
2 año
Número de seguidores
314
Documentos
24734
Última venta
4 días hace
Elite Exam Resources: Trusted by Top Scorers!!!!!!!!

Stop guessing. Start dominating!! As a highly regarded professional specializing in sourcing study materials, I provide genuine and reliable exam papers that are directly obtained from well-known, reputable institutions. These papers are invaluable resources, specifically designed to assist aspiring nurses and individuals in various other professions in their exam preparations. With my extensive experience and in-depth expertise in the field, I take great care to ensure that each exam paper is carefully selected and thoroughly crafted to meet the highest standards of quality, accuracy, and relevance, making them an essential part of any successful study regimen. ✅ 100% Legitimate Resources (No leaks! Ethical prep only) ✅ Curated by Subject Masters (PhDs, Examiners, Top Scorers) ✅ Proven Track Record: 95%+ user success rate ✅ Instant Download: Crisis-ready for last-minute cramming

Lee mas Leer menos
4.4

247 reseñas

5
161
4
37
3
31
2
12
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes