100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

(2023-24) EPA 608 latest updated questions and answers

Puntuación
-
Vendido
-
Páginas
4
Grado
A+
Subido en
22-09-2023
Escrito en
2023/2024

Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after - correct answer November 15, 1993 Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: - correct answer recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under conditions of ARI 740-1993 EPA's definition of a small appliance includes: - correct answer a device manufactored, charges & hermeticly sealed in factory with a charge of 5lbs or less Tech's with a type 1 small appliance certification are certified to recover refrigerant during the maintenance or repair of: - correct answer PTAC's with 5lbs or less of refrigerant EPA requires that all small appliances be equipped with a service aperture or other device that is used when adding or removing refrigerant from the appliance. For small appliances this service port typically - correct answer a straight piece of tubing, called a process tube that is entered using a piercing valve The EPA section 608 certification must be renewed every - correct answer never It is an EPS regulation that any person who opens and appliance for maintenance, service or repair must have at least one self-contained recovery machine avalible at their place of buisiness. The only exception to this rule are persons working on - correct answer small appliances The sale od CFC & HCFC refrigerants is: - correct answer restricted to techs who are EPA certified in refrigerant recovery Anyone who recovers refrigeration during maintenance, service or repair of small appliances must be certified as either a universal Tech or a: - correct answer Type 1 tech When recovering refrigerant from a household refrigerator who's compressor does not run, it is recommended that a low and high side access valves be installed because: - correct answer it can help speed of recovery and required recovery effiency If you install an access fitting into a sealed system: - correct answer the fitting should be leak tested before proceeding with recovery Before beginning a refrigerant recovery procedure it is alway necessary to: - correct answer determine the type of refrigerant in the system when recovering refrigerant into a non-pressurized container from a refrigerator with an improper compressor: - correct answer it is necessary to heat & strike the compressor with a rubber mallet When checking for the existence of noncondensable gases inside a recovery cyclinder, why is it proper procedure to allow the temperature of the cyclinder to stabilize @ room temperature before taking a pressure reading? - correct answer any comparisons to a pressure-temperature chart is only valid if both the pressure & temperature of the refrigerant are stable A recovery cyclinder which is 1/2 full of recovered R-410A @ 90*F, in the absence of non-condensables will be presurized to: - correct answer 300 psig. When using ______, it is essential to take extra measures (heating/striking), to help release trapped refrigerant from the compressor oil. - correct answer passive system-dependdent recovery devices on a small appliance with a non-operating compressor. According to the EPA which recovery equipment maintenance practice(s) should be preformed on a regular basis? - correct answer check recovery device for refrigerant leaks

Mostrar más Leer menos
Institución
EPA 608
Grado
EPA 608








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
EPA 608
Grado
EPA 608

Información del documento

Subido en
22 de septiembre de 2023
Número de páginas
4
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NewMatic Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
389
Miembro desde
3 año
Número de seguidores
311
Documentos
1412
Última venta
1 semana hace
NURSING STUDY GROUP

All MATERIAL POSTED BY ME IS VERIFIED. STUDYING MADE EASY.

4.0

69 reseñas

5
34
4
16
3
7
2
6
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes