On low pressure chillers, moisture typically enters the refrigerant system through - Answer air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - Answer 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - Answer ... A hydrostatic tube test kit is used to: - Answer determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. - Answer 35% Refrigerant recovery typically start with liquid recovery it is faster. - Answer ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - Answer 15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. - Answer 2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. - Answer local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? - Answer 16.9" Hg vacuum After recovering the liquid refrigerant you must: - Answer recover the vapor refrigerant According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - Answer 100 pounds Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: - Answer system water to freeze A system does not have to be evacuated all the way to the required level when: - Answer leaks in the appliance make evacuation to the prescribed level unattainable Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - Answer replacement of evaporator coil Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non major repair? - Answer warming the refrigerant If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. - Answer 25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should - Answer Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil The pressure corresponding to 32 F for R-123 - Answer 20 inches of HG vacuum When evacuating a system the use of too large a vacuum pump can cause? - Answer trapped water to freeze Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - Answer 35F During the evacuation of a system containing large amounts of moisture you can prevent freezing of this moisture by increasing the pressure with______gas - Answer nitrogen ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and mechanical ventilation beofre refrigerant concentrations exceed: - Answer the threshold limit valve and time weighted average The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning system is set at_______ - Answer 15 psi Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: - Answer pressurized nitrogen When a new system has been assembled, the first thing to do is: - Answer pressurize the system with inert gas and leak check EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds______ of the charge per year. - Answer 35% Prior to replacing the condenser coil in a high pressure system, the refrigerant was recovered and stored in a refillable container. The refrigerant: - Answer can probably be charged back into the system R-410A requires recovery tanks rated for at least: - Answer 400 psig to recover liquid refrigerant you must connect one hose to the - Answer liquid line The primary water source for cooling the condenser of a water-cooled recovery unit is: - Answer local municipal water supply After refrigerant liquid has been recovered from a system, any remaining vapor is: - Answer condensed by the recovery system With an air-cooled condenser on the roof of a building and the evaporator on the first floor, recovery should first occur: - Answer from the liquid line entering the evaporator the recovery of refrigerant from a system as a vapor only will minimize the loss of: - Answer oil When using recovery or recycling equipment that was made after 11-15-93 you must evacute a system containing MORE than 200 pounds of CFC-12 to ________ before making a major repair. - Answer 15 inches of HG vacuum When using recovery or recycling equipment that was made BEFORE 11-15-93 technicians must evacuate a unit that has a normal charge of 10 pounds of CFC-500 to _____ before disposing of the system. - Answer 4 inches of HG vacuum To change the compressor on a system cantaining 40 pounds R-500 using a recycling machine that was manufactured AFTER 11-15-93 you must isolate the compressor then: - Answer evacuate the isolated section of the system to 10 inches of vacuum and hold. If the system pressure does not rise, remove the compressor. Recycling and recovery equipment maufactured after 11-15-93 does not need an oil separator - Answer ... A system can be evacuated to only atmospheric pressure when: - Answer leaks in the appliance make the evacuation to the prescribed level unattainable To change the compressor on a system containing R-410A, you must isolate the compressor then: - Answer Evacuate the isolated section of the system to atmospheric pressure and hold. If system pressure does not rise, remove the compressor. System- dependent recovery equipment CANNOT be used when: - Answer the appliance contains over 15 pounds of refrigerant Moisture is removed a system by: - Answer using a filter drier When a unit is opened for servicing the ______ should always be replaced - Answer filter drier The backseating of a suction shutoff valvee will close the: - Answer guage port When charging an R-12 refrigeration system that uses a water cooled condensor, you must first charge with vapor to a pressure of at least _____ , before switching to a liquid charging. - Answer 35 psig A compressor heater is used to: - Answer reduce the amount of refrigerant in the lubricating oil While R-410A is a high pressure refrigerant, it can be stored in the back of your service van as long as: - Answer the temperature inside the vehicle does not exceed 125 degrees F. This is the same guidance given for R-22 and other common refrigerants. For what refrigerant is an equipment room refrigerant monitor required under ASHRAE standard 15? - Answer R-123 A reciprocating compressor should not be energized if the - Answer discharge service valve has closed What factor affects the speed of evacuation? - Answer the size of the equipment the ambient temperature the amount of moisture in the system The evacuation of a system is a method of: - Answer dehydration

Mostrar más Leer menos
Institución
EPA 608
Grado
EPA 608









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
EPA 608
Grado
EPA 608

Información del documento

Subido en
23 de agosto de 2023
Número de páginas
14
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Grademasters West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
114
Miembro desde
2 año
Número de seguidores
68
Documentos
2605
Última venta
1 mes hace
Grademasters

3.8

46 reseñas

5
20
4
9
3
11
2
2
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes