What is a cad cell? - Answer- Visual flame detector What does "in-step" mean? - Answer- The primary control start circuit is closed What is the voltage found at the TT terminals? - Answer- 24 volts What are the 8 steps on a no heat call? - Answer- Main fuse, oil burner fuse, customer emergency switch, oil tank, oil valves, high limit, thermostat, primary control. How much air is necessary to burn a gallon of #2 fuel oil? - Answer- 1540 cubic ft What is the normal pump pressure? - Answer- 100 psi How is combustion achieved? - Answer- Proper amount of oil, air, and ignition What is primary air? - Answer- Air mixed with oil before the nozzle. It is the atomizing air found on in low pressure burners. What is secondary air? - Answer- Fan air Does firbebrick come in different heat ratings? - Answer- Yes How should an oil tank be supported? - Answer- Rigid, non-combustable supports What is the wire gauged used on oil burner circuits? - Answer- 14 gauge min How is an oil burner wired? - Answer- Series; intermittent or interrupted. What does intermittent mean? - Answer- The transformers stays on throughout the burner cycle What does interrupted mean? - Answer- The transformer drops out after flame is established. Who approves oil burners in MA? - Answer- Any approved national testing lab What does the term Marshall mean? - Answer- State Fire Marshall What size vent pipe is required with a 2 inch fill pipe? - Answer- 2" min Can a vent pipe on an oil tank be smaller than the fill? - Answer- No, it can be larger but not smaller What is the minimum size of vent and fill pipes? - Answer- 1 1/4" Explain interrupted ignition - Answer- Transformer drops out after the flame is established What permits are available? - Answer- Install, store oil, and tank removal What are the elements found in fuel oil? - Answer- 85% Carbon and 15% Hydrogen What is fuel oil? - Answer- Hydro-carbon How must fuel oil be prepared for combustion? - Answer- It is atomized or vaporized and mixed with air What is a BTU? - Answer- The amount of heat necessary to rain 1 lb of water 1 degree Fahrenheit How many BTU's are in a gallon of #2 fuel oil? - Answer- 140,000 What determines the GPH of a nozzle? - Answer- The orifice What is a series circuit? - Answer- the current has only one path to travel What is a degree day? - Answer- 65 degrees F minus the daily average temp What is the flash point of #2 fuel oil? - Answer- 110 degrees Fahrenheit Can materials other than steel be used for fuel oil tanks? - Answer- Yes, if approved What does the word "approved" mean? - Answer- Accepted b y the Marshall of by the laboratory which is accepted by the Marshall When is a combustion efficiency test required by law? - Answer- After installs and routine maintenances What control shorts off the oil burner in the event of excessive temp in the appliance - Answer- High limit Name 3 functions of an oil pump? - Answer- Pick-up, pressurize, and strain oil How is an oil burner wired - Answer- Intermittent or interrupted How is an oil burner circuit wired? - Answer- Series When does an oil line have to be sleeved? - Answer- When it is buried or in contact with earth or cement What is the exception to overhead fireproofing? - Answer- Any AFUE (annualized fuel utilization efficiency) rated appliance What does "in-step" mean? - Answer- The primary control start circuit is closed What is the minimum size oil lines for residential burners - Answer- 3/8" OD, 3/8" IPS Is a permit required for the removal of an oil tank? - Answer- Yes Cross connections between two supply tanks shall not exceed ____________ gallons total. - Answer- 660 How is safety timing checked on a stack switch? - Answer- Remove the switch from its holder or disconnect terminal three, fire unit, and time its lockout. What is safety lockout timing firing under 3 GPHV ? - Answer- 15 seconds maximum. Is a combustion test required for tank replacement? - Answer- No Where should a thermal valve be installed on a supply line from the tank? - Answer- Connected at the bottom of the supply tank. What is a cadmium sulfide cell? - Answer- A resistor which changes its characteristics of conductivity in a direct proportion to the light striking it. What is the minimum size pipe that can be used for residential oil lines, and can right and left couplings be used? - Answer- 3/8" OD and 3/8" IPS minimum and right and left couplings are forbidden. What safety devices are found on a rotary burner? - Answer- A constant level valve and a solenoid valve. How is the oil flow regulated on a rotary burner? - Answer- The constant level valve When is a vent alarm used? - Answer- When gauge is not visible from fill When is a vent pipe required - Answer- All tanks that are larger than 10 gallons What must be done after an installation has been completed? - Answer- Submit a certificate of completion. When should your oil burner install certificate of completion be submitted? - Answer- Local fire department What is the time limit for submitting certificates of completion? - Answer- 72 hrs, excluding Saturday, Sunday, and all holidays. What is a confined space? - Answer- Less than 50 cu. ft. per 1,000 BTU's What is a gallon? - Answer- 231 cu. in. at a temp of 60 degrees Fahrenheit What are the element in air? - Answer- Nitrogen 80% or 79% Oxygen 20% or 21% How much air is required to burn a gallon of #2 fuel oil and why? - Answer- 1540 cu. ft.; This is the most amount of air needed to burn all the oil most efficiently. What kind of counts are used on oil tank installs? - Answer- Swing joints What are swing joints used on oil tanks? - Answer- To allow for movement or settlings without pipe or tank damage, and to enable piping to pitch back to tanks. What is the minimum distance that a burner must be from a tank? - Answer- 5' How many gallons of oil may be stored without a permit? - Answer- 10 gallons How much outside or replacement air is needed in a confined space - Answer- 140 sq." top and bottom per gallon per hour 1 sq." per 1000 BTU's How much outside or replacement air is needed in a boiler room of tight construction? - Answer- 28 sq." per gallon per hour 1 sq." per 5,000 BTU's What is a flame detector? - Answer- A device that sense flame thermally or visually What is a cad cell? - Answer- A visual flame sensor What is a purpose of a heat anticipator? - Answer- Prevents overheating Explain the differentials in a thermostat. - Answer- Mechanical - the operation of the helix; turns the appliance on and off Electrical - operation of the anticipator; prevents overheating What are the parts of an ignition assembly? - Answer- High voltage transformer, buss bars or high tension leads, insulators, and electrodes.

Mostrar más Leer menos
Institución
Oil Burner
Grado
Oil Burner









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Oil Burner
Grado
Oil Burner

Información del documento

Subido en
29 de mayo de 2023
Número de páginas
6
Escrito en
2022/2023
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$11.29
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Gordones22 Yala university
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
498
Miembro desde
3 año
Número de seguidores
351
Documentos
9500
Última venta
2 semanas hace

4.1

108 reseñas

5
63
4
17
3
13
2
4
1
11

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes