100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

DOD MWS cdc Latest Update Already Passed

Puntuación
-
Vendido
-
Páginas
25
Grado
A+
Subido en
24-05-2023
Escrito en
2022/2023

DOD MWS cdc Latest Update Already Passed identify five requirements for a MWS apparatus that can be found in NFPA 1901 1. an MWS apparatus equipped with fire pump must have a tank to pump line at least 2 in in diameter and capable of supplying the pump with 500 GPM unit at least 80% of water in the tank is emptied 2. NMWS apparatus must be equipped with at least one external fuel connection connected into the tank that allows the tank to be filled at a minimum rate of 1000 GPM 3. The external fuel connection should be equipped with a valve strainer and 30° elbow 4. valves that are 3 in or larger must be of the slow closing design 5. an MWS apparatus must have at least three large tank discharge capable of discharging 90% of the tank volume at an average rate of 1,000 GPM when checking the left front or right front side of the apparatus, don't forget to inspect: saddle tanks pre-service pump certification tests are conducted by: an independent testing agency when using a static body of water as your water source during fire apparatus service testing the water surface must not be more than_____feet above the center line of the pump intake and the water must be at least____feet deep 10,4 if the engine speed check provides the MWS apparatus is running at a different speed than that which it was originally rated, you need to: stop the testing until the problem is corrected when conducting a priming device test and using a pump of less than 1500 GPM, the priming device should be able to create the necessary vacuum_____seconds to lift water 10 ft through 20 ft of hard suction hose 30 The three parts of the pressure control test require you to close the flowing valves one at a time: And no less than 3 seconds and no more than 10 seconds The gauge and flow meter test compares flow meter readings with actual pilot tube readings. The two readings should differ no more than: 10% The tank to pump flow rate test measures whether the piping between an apparatus water tank and fire pump meets the minimum flow standard of: NFPA 1901 identify two most important reasons for maintaining good MWS apparatus records. 1. keeps everyone on the team informed about equipment conditions 2. helps determine whether equipment should be repaired / replaced. an MWS apparatus should be started with all electrical switches and the OFF position in order to: start the engine without a load. when testing the priming device on an MWS apparatus with a fire pump with the capacity less than 1500 GPM, the priming device should be able to create the necessary vacuum in 30 seconds to lift water 10 ft through: 20 ft of hard suction hose identify four pre-service tests for an MWS apparatus equipped with a fire pump 1. road test 2. independent pump certification test 3. hydrostatic test 4. purchase acceptance test identify three items that are checked for leaks during vacuum test. 1. priming device 2. hard suction hose 3. pump when performing a vacuum service test, once the engine is turned on, the column of mercury should fall no more than: 10 in and 5 minutes identify three pieces of equipment needed to conduct a service testing on an MWS apparatus equipped with a fire pump. 1. tachometer 2. smooth bore tip 3. external test gauges identify three critical items that should be included on an MWS apparatus daily inspection checklist 1. apparatus unit identification number

Mostrar más Leer menos
Institución
DOD MWS Cdc
Grado
DOD MWS cdc










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
DOD MWS cdc
Grado
DOD MWS cdc

Información del documento

Subido en
24 de mayo de 2023
Número de páginas
25
Escrito en
2022/2023
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BrilliantScores Chamberlain College Of Nursng
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2827
Miembro desde
3 año
Número de seguidores
2233
Documentos
16200
Última venta
1 día hace
latest updated documents, correct, verified & graded A study materials

get bundles, documents, test banks, case studies, shadow health's, ATIs, HESIs, study guides, summary, assignments & every kind of study materials.

3.8

774 reseñas

5
388
4
117
3
116
2
37
1
116

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes