100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

CBSPD Exam / CBSPD Sterile Processing Technician Certification Exam (CSPDT) all correctly answered.

Puntuación
-
Vendido
-
Páginas
30
Grado
A+
Subido en
18-06-2022
Escrito en
2021/2022

CBSPD Exam / CBSPD Sterile Processing Technician Certification Exam (CSPDT) all correctly answered.

Institución
CBSPD Sterile Processing Technician
Grado
CBSPD Sterile Processing Technician










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CBSPD Sterile Processing Technician
Grado
CBSPD Sterile Processing Technician

Información del documento

Subido en
18 de junio de 2022
Número de páginas
30
Escrito en
2021/2022
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CBSPD Exam 2022 / CBSPD Sterile Processing Technician Certification
Exam (CSPDT) all correctly answered.



Superheating can occur - answerIf the steam pressure is too low for the set temperature



Wet packs - answerWet steam can cause



68-73 degrees - answerAAMI recommends that the temperature in the sterilization area be:



30%-60% - answerAAMI recommends that the humidity is the sterilization area be



10 - answerThe recommended ventilation in the sterilization are is—— air exchanges per hour under
positive pressure



75-85/10/negative - answerAAMI recommends that the temperature in the sterilizer access area be
—- with — air exchanges per hour and under — pressure



Decon, the sterilizer access area, EVS closet - answerThe only 3 areas in SPD that should have negative
pressure are:



sterility - answer— is the absence of all forms of microbial life, including bacterial spores



One in a million; 10(-6) - answerAn item is considered sterile if there is less than —— chance that a
viable microorganism has survived the sterilization process. This is reflected numerically as —-



Sterility Assurance Level - answerSAL=

,Steam - answer— kills microorganisms by denature great the protein



steam sterilization - answer— is the most common form of sterilization for items that are heat- and
moisture-tolerant



saturated steam under pressure, time, and temperature - answerThree parameters of steam
sterilization cycles are



Dynamic-air-removal cycles - answer— are used in prevacuum sterilized and in steam-flush
pressure-pulse (SFPP)



Prevacuum sterilizers - answer— remove air by drawing series of vacuums with an injection of steam
between each vacuum pull.



Bowie-Dick test - answerPerformed daily to detect air leaks or inadequate air removal from
prevacuum sterilzers



Gravity-displacement cycles - answerIncoming steam displaces residual air through the drain at the
bottom of the sterilizer chamber:



Gravity-displacement - answerBecause there is no mechanical air removal in a —, a Bowie-Dick test is
not required for — or sterilizers



Boiler - answerIn most healthcare facilities, steam is generated inside of a:



60-80psig - answerThe required pressure of steam as it enters the jacket is usually:



28-30 lbs of pressure - answerFor a sterilizer operating at 270 degrees, the sterilizer gauge will show:



An insulating jacket - answerProvides heat inside the chamber to prevent condensation from forming

, on the chamber walls:



Heat-sensing thermometer - answerThe sterilizers - - - is locates in the drain line



The drain line - answerThe coldest part of sterilizer is



Bottom rack, drain line - answerAll PCDs should be placed on the —, directly over the —



On the bottom rack above the drain line - answerThe Bowie-Dick test pack is placed



Conditioning, sterilization/exposure/"holding, Exhaust, Drying - answerThe phases of steam
sterilization cycles are:



Conditioning phase - answerDuring this phase, air is removed from the sterilization chamber and
steam is injected



Sterilization/exposure/holding - answerIn this phase, the exposure temperature is maintained for the
prescribed amount of time.



Exhausted, Exhaust phase - answerAfter the exposure phase, steam is — from the sterilizer through the
chamber drain line is this phase:



Drying phase - answerAfter the steam has been exhausted, the sterilizer goes into the - of the cycle
which typically lasts about 30 minutes



• 4 minutes @ 270 and 28-30 psi

• 3 minutes @ 275 and 38-30 psi - answerThe cycle for wrapped items using Dynamic-air-removal
steam is:
$16.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
luzlinkuz Chamberlain University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1428
Miembro desde
4 año
Número de seguidores
849
Documentos
27650
Última venta
1 día hace

3.7

303 reseñas

5
131
4
61
3
54
2
17
1
40

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes