100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Otro

UNIT 2B- UNDERTAKE CALORIMETRY TO STUDY COOLING CURVES

Puntuación
-
Vendido
-
Páginas
10
Subido en
20-04-2022
Escrito en
2021/2022

the document focuses on calibration of equipment like liquid alcohol thermometer, calibrating at ice point and boiling point of water, calibration of temperature probe, The document also highlights on the risk assessment for heating and cooling. The methods for heating the stearic acid and constructing a cooling curve for stearic acid. The document analysis the graphs and predicts the melting points and there is detailed evaluation.

Mostrar más Leer menos
Institución
Grado









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Nivel de Estudio
Editores
Tema
Curso

Información del documento

Subido en
20 de abril de 2022
Número de páginas
10
Escrito en
2021/2022
Tipo
Otro
Personaje
Desconocido

Temas

Vista previa del contenido

RANSLEY FERNANDES ADMIN NO. 40202


ASSIGNMENT TITLE- KEEPING UP THE STANDARDS


LEARNING AIM B- UNDERTAKE CALORIMETRY TO STUDY COOLING CURVES


INTRODUCTION
As an appointed technical assistant, my role is to make sure that all the
equipment are calibrated and all chemicals are safe. I need to demonstrate the
ability to utilise calorimeter and to determine the data, analyse and assess the
cooling rate of substances. We should make sure that there is evidence of
practical skills analysis and assessment in a report.



METHODS TO CALIBRATE EQUIPMENTS AND RESULTS
 LIQUID ALCOHOL THERMOMETER

CALIBRATION AT ICE POINT OF WATER
 Firstly, we should fill the Styrofoam container with
ice which should be crushed.
 Now we should add the distilled water which is
previously cooled and cover the ice, we must not
add water until the ice starts to float.
 We should stir the mixture of ice and water
thoroughly.
 Now we should hang the thermometer by a string
from a clamp connected to a ring stand till it is
suitably placed into the ice water.
 We should let the temperature stabilise; nearly 10
minutes are needed to create thermal equilibrium.
 When the temperature is balanced after 3 minutes,
we should record the temperature accurately.
 The ice point of water is stable at 0.00 degree
Celsius.



CALIBRATION AT BOILING POINT OF WATER

, RANSLEY FERNANDES ADMIN NO. 40202


 Initially we should arrange a hot plate on which the 500 millilitres of Florence
flask is resting. The Florence flask should have a support of a clamp from a
ring stand.
 We should fill the Florence flask with distilled water until it is half full. We
should also add few boiling chips in order to encourage smooth boiling.
 Now carefully hang the thermometer by the help of the ring stand like
before; we should make sure that the immersion mark is at the neck of the
Florence flask.
 After this, switch on the hot plate and let the temperature reach to its boiling
point.
 We should let the temperature that is on the temperature to balance, nearly
10 minutes are needed to achieve rolling-boil.
 After 3 minutes of stabilising the temperature, we should record the
temperature to right precision.
 The boiling point of water is greatly delicate to the pressure of atmosphere.
Therefore will be given the day’s atmospheric pressure.




TEMPERATURE PROBE
The temperature probes are used to
check the temperature of the meat and
liquid, the temperature probe is used to
see if the meat is at suitable temperature
to be served.
In order to maintain accuracy the
temperature probe is required to
calibrate and tested.
 First, we put 250 mL of water in the
saucepan and boil it on the hob.
 We than put some ice cubes below one glass
 Now, we pour half of the water in each glass
 Put the thermometer into the hot water and check the temperature. We should
adjust the nut in order to make the thermometer read 100 degree Celsius.
 We also put the thermometer into the ice water and will check the temperature. We
should adjust the nut again to make the thermometer read 0 degree Celsius.
 We should repeat the experiment until we get the correct reading on the
thermometer.
$25.70
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ransleyferns12 Lancaster University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
32
Miembro desde
3 año
Número de seguidores
28
Documentos
14
Última venta
10 meses hace

4.3

8 reseñas

5
4
4
2
3
2
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes