100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Clinical Laboratory Chemistry - Complete test bank - exam questions - quizzes (updated 2022)

Puntuación
-
Vendido
-
Páginas
223
Grado
A+
Subido en
17-02-2022
Escrito en
2021/2022

Description: - In the file you can find extensive number of exam questions. - Supports multiple editions (newer and older) - Different difficulty levels ranging from easy to extremely difficult - The whole book is covered (All chapters) - Questions you can expect to see: Multiple choice questions, Problem solving, essays, Fill in the blanks, and True/False. - This test bank is a great tool to get ready for your upcoming exam. *** If you have any questions or special request feel free to send a private message

Mostrar más Leer menos
Institución
Grado











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Libro relacionado

Escuela, estudio y materia

Institución
Grado

Información del documento

Subido en
17 de febrero de 2022
Número de páginas
223
Escrito en
2021/2022
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Clinical Laboratory Chemistry, 2e (Sunheimer)

Chapter 1 Laboratory Basics



1) Ion-exchange filters remove which of the following from a water source?

A) Ions to reduce the mineral content of water

B) Lead

C) Organic solvents.

D) Bacteria

Answer: A



2) Activated carbon filters remove:

A) Ions from water.

B) Organic compounds from water.

C) Acids and bases from water.

D) Large particulates from water.

Answer: B



3) A 0.22-micron filter will remove:

A) Particles with a diameter of 0.01 microns.

B) Particles with a diameter of 0.01 nanometers.

C) Particles with a diameter of 2.2 microns.

D) Only sodium chloride crystals.

Answer: C



4) The unit of resistivity is:

,A) Amperes.

B) Volts.

C) Coulombs.

D) MΩ ∙ cm.

Answer: D



5) Microbiological impurities in source water are reported in which format?

A) Colony forming units per mL (Cfu/mL)

B) Total organic carbon (TOC) in ng/g

C) milligrams of SiO2

D) Resistivity.

Answer: A



6) According to CLSI, the resistivity of clinical laboratory reagent water (CLRW) must
be:

A) > 100 milliamps.

B) < 10 millivolts.

C) > 10 MΩ ∙ cm.

D) < 10 MΩ ∙ cm.

Answer: C

,7) Which of the following should not be storied in borosilicate glass because it will etch
the inside surface of the glass container?

A) Saline

B) Strong bases (caustics)

C) Clinical laboratory reagent water

D) Weak acids

Answer: B

8) Low actinic glassware has which of the following properties?

A) High thermal resistance with no color added to the glass

B) Low thermal resistance with a green-yellow color added as an integral part of the glass

C) High thermal resistance with a blue color added as an integral part of the glass

D) High thermal resistance with an amber or red color added as an integral part of the
glass

Answer: D



9) Care must be taken before selecting polyethylene plastic for use as test tubes and
disposable transfer pipets because:

A) Polyethylene can bind or absorb proteins, dyes, stains, and picric acid.

B) Polyethylene does not bind or absorb proteins, dyes, stains, and picric acid.

C) Polyethylene cannot be used to pipet serum.

D) Polyethylene forms insoluble salts in the presence of sodium chloride.

Answer: A



10) Which of the following classes of glassware, including pipets, is manufactured and
calibrated to deliver the most accurate volume of liquid?

A) A

B) B

, C) AA

D) C

Answer: A



11) A to deliver or TD pipet is designed to:

A) Allow the user to remove a portion of the sample in the tip for better accuracy.

B) Be vigorously tapped against the test tube after all the liquid is removed.

C) Drain by gravity.

D) Be refilled or rinsed out with the appropriate solvent after the initial liquid has been
drained from the pipet.

Answer: C



12) Which of the following devices is used to calibrate laboratory thermometers?

A) Barometer

B) Gallium melting point cell

C) Titanium freezing point cell

D) Platinum cathode voltmeter

Answer: B
$40.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TestBanks2022 Harvard University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2131
Miembro desde
4 año
Número de seguidores
1700
Documentos
2242
Última venta
2 días hace

4.0

344 reseñas

5
183
4
59
3
46
2
18
1
38

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes