Hemodynamics & Medical Emergencies

Shock

 This life-threatening condition can result in damage to multiple organs.

 The condition requires immediate medical treatment; it can worsen rapidly if it goes untreated,
resulting in death.

 Shock takes three main forms: hypovolemic, cardiogenic, and vasogenic:

 Hypovolemic shock is caused by internal or external blood or fluid loss.

 Cardiogenic shock is associated with cardiac problems; in this type of shock the heart is unable
to pump sufficient blood for the body’€™s needs.

 Vasogenic shock results from massive vasodilation; anaphylactic shock (associated with an
allergic reaction), septic shock (associated with infection), and neurogenic shock (associated with
injury to the neurological system) are all types of vasogenic shock.




In the event of shock, the nurse should do the following:

 Elevate the legs

 Notify the physician

 Determine and treat the cause of shock

 Administer oxygen, as prescribed

 Monitor level of consciousness

 Monitor vital signs for increased pulse or decreased blood pressure

 Monitor intake and output

 Assess color, temperature, turgor, and moisture of the skin and mucous membranes

 Administer IV fluids, blood, and colloid solutions, as prescribed

, Hemodynamic Measurements

 Both, invasive and non-invasive techniques can be used to measure a patient’s hemodynamic
status.

 The purpose of invasive hemodynamic monitoring is to detect and monitor changes in
intravascular pressures and cardiac output. This allows for optimum patient management.

 Preload: amount of blood returning to the heart and filling the ventricles at the end of diastole.
Increased preload increases the stroke volume, ventricular work, and myocardial O2 demand.

 Afterload: pressure ventricles has to overcome to eject its contents into the aortic (Systemic
Vascular Resistance) and pulmonary (Pulmonary Vascular Resistance) valves during systole.
Increases afterload causes the heart to work harder and demand more O2. It eventually causes
to a decrease in ventricular compliance and stroke volume.

Intraarterial Blood Pressure Monitoring

 Monitoring is indicated for any major condition that compromises cardiac output, tissue
perfusion, or fluid volume status.

 An arterial pressure waveform is displayed on a bedside monitor that shows continuous
measurement of systolic, diastolic, and mean arterial blood pressures (BPs).

 Mean arterial pressure (MAP) is an approximation of the average pressure in the systemic
circulation throughout the cardiac cycle; it must be at least 60 mm Hg for adequate organ
perfusion.

 Direct arterial access for the measurement of pressures is helpful for clients who require
frequent blood sampling, particularly for arterial blood gases.

Central venous pressure (CVP) is the pressure within the superior vena cava; this reading reflects
the pressure under which blood is returned to the superior vena cava and right atrium.

 CVP is measured with the use of a central venous line in the superior vena cava or a balloon
flotation catheter in the pulmonary artery.

 Normal CVP pressure is 2 to 8 mm Hg.

 An increased CVP indicates an increase in blood volume as a result of sodium and water
retention, excessive intravenous (IV) fluids, alterations in fluid balance, or renal failure.

 Decreased CVP indicates a decrease in circulating blood volume and may be the result of fluid
imbalance, hemorrhage, or severe vasodilation with pooling of blood in the extremities that
limits venous return.

Pulmonary Artery Pressure

 A pulmonary artery catheter is used to measure right atrial and indirect left atrial pressures or
pulmonary artery wedge pressure (PAWP), which is also known as pulmonary artery occlusive
pressure (PAOP).

 PAWP normally ranges between 6 and 12 mm Hg.

 Normal right atrial (RA) pressure ranges from 2 to 8 mm Hg.

 Normal pulmonary artery pressure (PAP) ranges from 15 to 26 mmHg systolic/5 to 15 mmHg
diastolic.

Información del documento

Subido en
4 de julio de 2021
Número de páginas
10
Escrito en
2021/2022
Tipo
Otro
Personaje
Desconocido
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Vendido
247
Seguidores
221
Artículos
1737
Última venta
3 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes