1. In a hospital air conditioning system, a technician is troubleshooting a
chilled-water air handling unit that is producing warm supply air. The
chilled-water valve is open, the pump is operating, and the fan is
running normally. The technician measures a very small temperature
difference between chilled-water supply and return lines. Which
condition is the MOST likely cause of poor cooling performance?

A. Excessive airflow across the coil
B. Dirty or fouled evaporator coil restricting heat transfer
C. Incorrect rotation of the supply fan motor
D. Overheated condenser motor windings

Answer: B. Dirty or fouled evaporator coil restricting heat transfer

,A restricted or dirty coil reduces the ability of refrigerant or chilled water to
absorb heat, causing poor temperature transfer and a reduced
temperature difference across the coil.

2. A hospital air conditioning mechanic is performing preventive
maintenance on a variable air volume (VAV) system. The mechanic
notices that several terminal boxes are not maintaining room
temperature even though the air handling unit is operating correctly.
Which component should be inspected first?

A. VAV damper actuator and airflow sensor
B. Compressor crankcase heater
C. Condenser fan blade pitch
D. Refrigerant receiver level

Answer: A. VAV damper actuator and airflow sensor

VAV systems regulate room conditions by adjusting airflow through
dampers controlled by actuators and sensors; failures in these components
commonly cause incorrect space temperatures.

3. A refrigeration circuit in a hospital split air conditioning system shows
high suction pressure and low superheat. What is the most likely
cause?

A. Refrigerant undercharge
B. Restricted airflow over the evaporator

,C. Overfeeding of refrigerant into the evaporator
D. Blocked condenser coil

Answer: C. Overfeeding of refrigerant into the evaporator

Excess refrigerant entering the evaporator causes incomplete vaporization,
resulting in low superheat and elevated suction pressure.

4. Before servicing electrical components of an air conditioning unit in a
healthcare facility, the mechanic must follow lockout/tagout
procedures. The primary purpose of lockout/tagout is to:

A. Increase equipment operating efficiency
B. Prevent unexpected energization of equipment during maintenance
C. Reduce refrigerant pressure
D. Improve thermostat calibration

Answer: B. Prevent unexpected energization of equipment during
maintenance

Lockout/tagout protects workers by ensuring equipment cannot
accidentally start or become energized while maintenance work is being
performed.

5. A technician is charging a refrigeration system using a cylinder of
blended refrigerant. Why must the refrigerant generally be removed
from the cylinder as a liquid during charging?

, A. Liquid refrigerant improves compressor lubrication
B. Vapor charging changes the refrigerant composition of blends
C. Liquid charging prevents all leaks
D. Vapor charging increases system capacity

Answer: B. Vapor charging changes the refrigerant composition of blends

Many blended refrigerants contain multiple components that can separate;
charging as vapor may alter the refrigerant mixture and reduce system
performance.

6. A hospital operating room requires positive pressure relative to
surrounding areas. The HVAC mechanic understands that maintaining
positive pressure requires:

A. Exhaust airflow greater than supply airflow
B. Supply airflow greater than exhaust airflow
C. Closing all return air openings
D. Eliminating outside air intake

Answer: B. Supply airflow greater than exhaust airflow

Positive pressure rooms maintain higher pressure by supplying more
conditioned air than is exhausted, preventing contaminants from entering
the space.

7. When measuring superheat on a refrigeration system, the mechanic
should compare:

Información del documento

Subido en
11 de agosto de 2026
Número de páginas
44
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$24.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Guestt
4.4
(5)
Vendido
11
Seguidores
0
Artículos
2091
Última venta
1 semana hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes