2026

Where do leaks commonly occur in low pressure systems?

a. Evaporator

b. Condenser

c. Purge unit

d. Gaskets or fittings - d. Gaskets or fittings



Where do leaks commonly occur in open-drive type compressor systems?

a. Evaporator

b. Condenser

c. Shaft seal

d. Cooling tower - c. Shaft seal



Does refrigerant go out of the system in low pressure systems or does air and

moisture go in?

a. Refrigerant escapes through low pressure leaks.

b. Air and moisture enter the refrigeration system because it operates

in a vacuum

c. Refrigerant leaks out through shaft seals and gaskets. - b. Air and moisture enter the
refrigeration system because it operates

,in a vacuum



When should a low pressure system be leak checked according to ASHRAE

guideline 3-1996?

a. There are specific recommendations.

b. During pressure checks

c. When the system rises from 1 mm Hg to a level above 2.5 mm Hg

during vacuum testing

d. Leak check every year - c. When the system rises from 1 mm Hg to a level above 2.5 mm Hg
during vacuum testing



What does a purge unit do and what is a high efficiency purge unit?

a. Removes the refrigerant from the system. High efficiency purge system

will expel large quantities of refrigerant

b. Removes the refrigerant from the system. High efficiency purge system

will expel very little refrigerant

c. Removes the oil from the system. High efficiency purge system will expel

very little refrigerant

d. Removes the air from the system. High efficiency purge system will

expel very little refrigerant - d. Removes the air from the system. High efficiency purge system
will

expel very little refrigerant



How does a centrifugal compressor purge unit work?

a. Takes its suction from the top of the evaporator, removes the air from the

system, and returns the refrigerant to the evaporator

b. Takes its suction from the top of the chiller barrel, removes the air from the

, system, and returns the refrigerant to the evaporator

c. Takes its suction from the top of the compressor suction, removes the air

from the system, and returns the refrigerant to the evaporator

d. Takes its suction from the top of the condenser, removes the air

from the system, and returns the refrigerant to the evaporator - d. Takes its suction from the top
of the condenser, removes the air

from the system, and returns the refrigerant to the evaporator



What are visible ways to check for leaks in a low pressure system?

a. Excessive running of a purge system.

b. Continuous excessive moisture in the purge unit could indicate a leak in

the condenser or the chiller barrel.

c. High head pressure

d. All the above - d. All the above



What needs to be done to leak check a low pressure system?

a. Increase the pressure in the system by the use of nitrogen

b. Increase the pressure in the system by the use of oxygen

c. Increase the pressure in the system by the use of controlled hot

water or heater blankets

d. Increase the pressure in the system by the use of boiler hot water - c. Increase the pressure in
the system by the use of controlled hot

water or heater blankets



What are ways you can increase the pressure in the system?

a. controlled hot water

b. heater blankets

Información del documento

Subido en
4 de agosto de 2026
Número de páginas
16
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$14.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Vendido
23
Seguidores
3
Artículos
2157
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes