Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 6 páginas
Examen

AACN NEWEST 2026/2027 EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS | GRADED A+

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

AACN NEWEST 2026/2027 EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS | GRADED A+

Vista previa del contenido

AACN 2026/2027 Updated Exam Review & Practice Question | Graded A+


Endocardium - ANSWER inner layer of the heart



Myocardium - ANSWER thick, middle layer of the heart



Epicardium - ANSWER outer surface of the heart muscle



RCA - ANSWER extends to the back of the heart and perfuses the posterior of the heart



ECG prep - ANSWER alcohol before skin prep



Time it takes the paper to come out of the EKG machine? - ANSWER 25 mm/s



Vertical axis - ANSWER voltage--small box = 0.1 mv



Horizontal axis - ANSWER time--small box = 0.4 sec



How often are tick marks? - ANSWER every 3 seconds



Isoelectric line - ANSWER electrical charges in the heart are equal



5 lead - ANSWER smoke over fire, clouds over grass, brown in the middle



QT prolongation - ANSWER - can cause torsades

- can be affected by drugs (antibiotics, Antidysrhythmic , antipsychotic drugs)



Atrial pacemaker fires... - ANSWER before the P wave



Ventricular pacemaker fires... - ANSWER before the QRS complex

, Threshold - ANSWER the lowest amount of energy needed to produce a "capture"



Failure to pace - ANSWER no pacemaker activity, it is not firing. This could be a sensitivity problem or
a mechanical issue



Failure to capture - ANSWER the pacemaker is firing but no P wave or QRS complex follows the pacer
spike. The impulse is not strong enough to depolarize the heart (increasing the mA will troubleshoot
this problem)



Failure to sense - ANSWER If the pacer spike is in the T wave, it is failure to sense



Over-sensing - ANSWER - the pacemaker is too sensitive

- ex. pt is coughing and the pace maker thinks it's the pt's HR

- to decrease the sensitivity you must INCREASE the mV



too sensistive - ANSWER INCREASE the mV



Under-sensing - ANSWER - the pacemaker is not sensitive enough

- ex. fixed pace at 75 but pt is running up the stairs, their HR is climbing, and the pacemaker is not
picking it up

- to increase the sensitivity you must DECREASE the mV



Not sensitive enough - ANSWER DECREASE the mV



Pulse generator - ANSWER initiates the impulse, also contains the battery



Single Chamber Atrial pacing - ANSWER - spike followed by p wave

- AAI

- AAT



Single Chamber Ventricular pacing - ANSWER - spike followed by QRS

- VVI

Información del documento

Subido en
4 de agosto de 2026
Número de páginas
6
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
1
Artículos
202
Última venta
-


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes