Prepare for NC H3-1 Section 17 (Residential & Light Commercial) with this comprehensive 2026 Latest Study Guide. This resource features well-organized practice questions and detailed answers covering the essential concepts commonly tested in residential and light commercial HVAC licensing and certification exams. Topics include HVAC system fundamentals, heating and cooling equipment, electrical controls, refrigeration principles, duct design, airflow, ventilation, load calculations, installation standards, maintenance procedures, troubleshooting techniques, safety regulations, energy efficiency, applicable mechanical codes, and industry best practices. Designed to reinforce technical knowledge, strengthen problem-solving skills, and support effective preparation for licensing and certification examinations, this study guide is an excellent review resource for HVAC technicians, apprentices, and contractors.

Mostrar más Leer menos
Institución
NC H3-1 Section 17 Practice
Grado
NC H3-1 Section 17 Practice

Vista previa del contenido

NC H3-1 Section 17 Practice Questions (Residential/Light
Commercial) | Most Tested Questions & 100% Correct
Answers | 2026 Update
1. To find the static pressure loss for a duct section, the total equivalent length
of the duct section is divided by and multiplied by the design static pressure
drop that was used to size the duct.

100

1000

50

10

2. If a restaurant decides to install two 10-foot long medium-duty kitchen hoods,
what would be the total required CFM of exhaust air for both hoods?

3000 cfm

10000 cfm

5000 cfm

2000 cfm

3. What is the maximum CFM for a 24" round spiral duct according to the ACCA
manual-Q?

4600 cfm

5800 cfm

3800 cfm

6000 cfm

4. When a sediment trap is used on a gas piping it must be installed ?

, Downstream of equipment shut off valve as possible
By the equipment manufacture

Upstream of equipment shut off valve as possible

Sediment traps are not required


5. Describe the process used to determine the equivalent round duct size from
the given rectangular duct dimensions.

The equivalent round duct size is based solely on the height of the
rectangular duct.

The equivalent round duct size is simply the average of the two
dimensions.

The equivalent round duct size is determined by the volume of air it
can carry.

The equivalent round duct size is calculated using the dimensions of
the rectangular duct and accounting for insulation.

6. Which code specifies the installation requirements for smoke detectors?

2018 NC fire code

2018 NC mechanical code

NFPA 72

NFPA 70

7. If the insulation quality of the building in Asheville is improved, how would
that likely affect the heat loss calculation?

The heat loss would fluctuate unpredictably.

The heat loss would remain the same.

, The heat loss would increase.
The heat loss would decrease.

8. What is the design friction rate for an air handling unit at an external static
pressure of .3 IWC and a total equivalent length of 480 feet?

0.06

0.08

0.10

0.04

9. What is the required amount of combustion air for a 60,000 btu/hr furnace
when using indoor air?

7000 cubic feet of air

8000 cubic feet of air

4950 cubic feet of air

5250 cubic feet of air

10. Where should dampers be installed in a residential duct system for proper
balancing?

At the trunk entrance fitting

At the return air stack head

At the box collar

Never install dampers in return ducts

11. If the pressure drop across a wet residential unitary evaporator coil increases
to 0.60 IWC while maintaining the same air flow, what might this indicate
about the coil's condition?

, The refrigerant levels in the system are too high.
The coil is functioning optimally and requires no maintenance.

The coil may be dirty or clogged, affecting airflow and efficiency.

The air flow has increased significantly beyond 1750 cfm.


12. If a duct heater is installed 5 feet away from the air handling unit, what
potential issues could arise?

Easier maintenance access

Improved air circulation

No issues will arise

Inefficient heating and increased heat loss

13. You are installing a medium-duty kitchen hood in a commercial application.
The hood type is a single island canopy hood. The hood is 10-feet long so
how many cfm of total exhaust air will be required?

2500 cfm

2000 cfm

3000 cfm

5000 cfm

14. If an HVAC system has a cooling load of 40,000 BTU/hr and the blower
produces 1200 CFM, what would be the cooling factor?

0.035

0.030

0.033

0.0333

Escuela, estudio y materia

Institución
NC H3-1 Section 17 Practice
Grado
NC H3-1 Section 17 Practice

Información del documento

Subido en
25 de julio de 2026
Número de páginas
85
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$21.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
ExamInsight

Conoce al vendedor

Seller avatar
ExamInsight Herzing University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
-
Miembro desde
5 días
Número de seguidores
0
Documentos
187
Última venta
-
ExamInsight Test Banks, Exam Notes & Revision Resources

Welcome to ExamInsight, a trusted academic resource hub for students seeking high-quality test banks, exam documents, revision notes, summaries, past papers, and study guides. Our materials are carefully selected and well organized to support effective exam preparation, concept review, and time-saving revision. ExamInsight provides reliable materials designed to help students study smarter, build confidence, and improve academic performance.

Lee mas Leer menos
0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes