Which of the following compressors are considered a dynamic compressor?



a. Centrifugal

b. Reciprocating

d. Rotary

c. Scroll - ANSWER✔ a (Centrifugal)



What is the condition of the refrigerant as it enters and leaves the condensing coil of a typical light
commercial HVAC system?



a. Vapor / liquid

b. Superheated vapor / sub cooled liquid

c. Saturated vapor / saturated liquid

d. Hot gas / cool liquid - ANSWER✔ b (Superheated vapor / sub cooled liquid)



Which one of the following are considered the best metering device of the industry?



a. Capillary tube

b. Thermal expansion valve

d. Constant pressure expansion valve

c. Electronic expansion valve - ANSWER✔ b (Thermal expansion valve)



Which of the following types of refrigeration oil would you expect to find in a typical commercial R-134a
freezer?

,a. Mineral 150

b. POE

c. AB

d. Mineral 300 - ANSWER✔ b (POE. Newer refrigerant systems today using R-134a and R-410a use a
synthetic Polyester POE oil. Older refrigeration systems using R-12, R-502, and R-22 use a mineral based
oil.)



Where does the small single port tube and the larger middle port tube go on a typical residential or light
commercial reversing valve?



a. Inlet outdoor coil / inlet indoor coil

b. Compressor discharge / compressor suction

c. Compressor suction / compressor discharge

c. Outlet indoor coil / outlet outdoor coil - ANSWER✔ b (Compressor discharge / compressor suction)



If you were working on a 3.5 ton split system, with a 125,000 BTH/H horizontal furnace, and you had a
low suction pressure, low discharge pressure, high superheat, and high subcooling, what is wrong with
the system?



a. low refrigerant charge

b. overcharged system

c. overfeeding metering device

d. restricted liquid line filter/drier - ANSWER✔ d (restricted liquid line filter/drier)



If you were working on a 3.5 ton split system, with a 125,000 BTU/H horizontal furnace, and you had
high suction pressure, low discharge pressure, low superheat, and low subcooling, what is wrong with
the system?



a. low refrigerant charge

b. overcharged system

c. overfeeding metering device

, d. restricted liquid line filter/drier - ANSWER✔ c (overfeeding metering device)



If you were working on a 3.5 ton split system, with a 125,000 BTU/H horizontal furnace, and you had
high suction pressure, low discharge pressure, high superheat, and low subcooling, what is wrong with
the system?



a. weak compressor valves

b. stuck reversing valve

c. bad indoor check valve

d. bad outdoor check valve - ANSWER✔ a (weak compressor valves)



If you were working on a 3.5 ton split system, with a 125,000 BTU/H horizontal furnace, and you had
high suction pressure, high discharge pressure, low superheat, and high subcooling, what is wrong with
the system?



a. low refrigerant charge

b. overcharged system

c. overfeeding metering device

d. restricted liquid line filter/drier - ANSWER✔ b (overcharge system)



You are working on a heat pump package unit and come across a charge compensator, what is it used
for?



a. to compensate for a low refrigerant charge

b. to compensate for an overcharged system

c. to compensate charge in the heating cycle

d. to compensate charge in the cooling cycle - ANSWER✔ d (to compensate charge in the cooling
cycle)



You are working on a heat pump package unit with a charge compensator, how is the charge
compensator connected to the refrigeration system?

Escuela, estudio y materia

Institución
NATE
Grado
NATE

Información del documento

Subido en
25 de julio de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
THESTUDYNEST

Conoce al vendedor

Seller avatar
THESTUDYNEST Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
-
Miembro desde
3 semanas
Número de seguidores
1
Documentos
220
Última venta
-
THESTUDY NEST

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes