Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 51 páginas
Examen

PROPANE PRACTICE TESTS|COMPREHENSIVE Q&A FOR CERTIFICATION SUCCESS 2026

Document preview thumbnail
Vista previa 4 fuera de 51 páginas

PROPANE PRACTICE TESTS|COMPREHENSIVE Q&A FOR CERTIFICATION SUCCESS 2026

Vista previa del contenido

1|Page



PROPANE PRACTICE
TESTS|COMPREHENSIVE Q&A FOR
CERTIFICATION SUCCESS 2026




Re-circulating direct gas-fired industrial air heaters shall NOT ____________ in

buildings that contain flammable solids, gases, explosive materials, or substances

that may become toxic when exposed to flame. - correct-answer - Re-circulate

room air




NFPA 54/ANSI Z223.1, National Fuel Gas Code, shall be administered and

enforced by _____________ designated by the governing authority. - correct-

answer - The authority having jurisdiction




A system being leak tested should show no increase or decrease in the pressure

reading for a period of ______________. - correct-answer - 3 minutes

,2|Page




____________ are appliances that are constructed and installed so that all air for

combustion is derived directly from the outside atmosphere and all flue gases are

discharged outdoors. - correct-answer - Direct vent appliances




A vent connector shall NOT be connected to a chimney flue serving a fireplace

unless the fireplace flue opening is _____________. - correct-answer -

Permanently sealed




Fuel containers shall be ____________ to prevent jarring loose. - correct-answer -

Mounted




ASME containers and cylinders on vehicles utilized for other than engine fuel

systems, shall NOT be ____________ inside the vehicle. - correct-answer - Stored,

installed, or transported

,3|Page




Containers used in a public building undergoing minor renovations shall NOT have

more than a maximum propane capacity of ______________ and the number of

cylinders shall NOT exceed the number of workers assigned to use the LP gas. -

correct-answer - 20 lbs




Field welding on containers shall be limited to attachments on ____________

installed by the manufacturer. - correct-answer - Non-pressure parts




During the hours of the day the public is permitted in a building undergoing minor

renovations, the cylinders shall NOT be ____________. - correct-answer - Left

unattended




Portable heaters shall be equipped with an approved ________ to shut off the

flow of gas to the main burner in the event of flame extinguishment or

combustion failure. - correct-answer - Automatic shutoff

, 4|Page




A ___________ for medium-heat equipment shall extend at least 10 ft higher

than any portion of any building with 25 ft. - correct-answer - Chimney




____________ is gas piping that, when in place in a finished building, would

require removal of permanent construction to gain access to the piping. - correct-

answer - Concealed piping




A type B-W gas vent shall terminate at least _______ in vertical height above the

bottom of the wall frame. - correct-answer - 12 feet




A gas vent extending through an exterior wall shall NOT terminate adjacent to the

wall or below ______________. - correct-answer - Eaves or Parapets

Información del documento

Subido en
24 de julio de 2026
Número de páginas
51
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DRVERITY
3.8
(12)
Vendido
104
Seguidores
0
Artículos
8165
Última venta
5 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes