Who is the individual responsible for reviewing all inspection
and testing reports
prior to the use of new, additional, renovated, or temporary
medical gas and
vacuum
installations? A.
Inspector of
record
B. Installing
contractor
C. On-site
verifier
D. Responsible facility authority –ANSWER- D.
Responsible facility authority
When so trying positive pressure cylinders in an outdoor
enclosure, the enclosure shall meet which of the following
requirements?
A. Be built with a minimum of two exits
B. Be (covered in picture) cylinders from the soil
,C. Have (covered in picture) feet of space for cylinder storage -
ANSWER- B. Be (covered in picture) cylinders from the soil
A Central Supply system with a storage capacity of more than
3200 pounds at normal temperature and pressure best
describes which system?
A. Bulk Cryogenic Fluid Central Supply
B. Bulk Nitrous Oxide Central Supply
C. Cylinder System
D. Micro Bulk Cryogenic Fluid Central Supply - ANSWER- B.
Bulk Nitrous Oxide Central Supply
Where liquid ring compressors are used, air receivers shall be
equipped with a high water level sensor that activates
a(n)______alarm indicator.
A. Area
B. Local
C. Master
D. Pressure - ANSWER- B. Local
Instrument air systems shall activate the alarm systems when
the dew point of
system pressure exceeds how many degrees
Fahrenheit?
A. -
20°
B. -
22°
,C. -
24°
D. -26° -
ANSWER-B.
-22°
Performance qualification of braziers shall remain in effect
indefinitely unless the brazed does NOT braze with the
qualified procedure for longer than what period of time? A. 6
months
B. 12 months
C. 18 months
D. 24 months - ANSWER-A. 6 months
Pipe labels shall be located at a maximum interval of
how many feet?
A. 10
B. 15
C.
20
D. 25 - C.
20
The installation of medical gas and vacuum systems shall be
made by experienced, qualified and competent installers.
Installers shall be certified to the requirements of which
Code/Standard?
A. ASME Section IX
, B. ASSE Standard
6010
C. AWS
B31.3
D. Both ASME Section IX and ASSE Standard - ANSWER-
B. ASSE Standard 6010
Where medical gas systems operate at pressures other than the
standard gauge pressures, which of these is required to be
listed on the station outlet identification?
A. A chemical symbol ONLY
B. Name of the gas and operation pressure
C. Non standard operation pressure and system type
D. The gas registration number and a number to call in
emergencies - ANSWER-C. Non standard operation pressure
and system type
A gauge reading exceeding 200 psi in a piping system is
defined as which type of pressure? A. Absolute
B. Gauge
C. High
D. Positive - ANSWER-C. High
Compressed gas cylinders much meet all EXCEPT which of the
following criteria in order to be acceptable for use in an acute
health care facility?
A. Contents are appropriately identified with stencils
B. Labels for liquid containers shall have 2-inch lettering
C. Labels shall not be altered or removed