CRT RRT NBRC UPDATED CORE REVIEW QUESTIONS
AND ANSWERS SURE A+
✔✔Positive Expiratory Pressure (PEP) Therapy - ✔✔-applying positive pressure using a
one-way inspiratory valve and a one-way expiratory resistor
-expiratory pressure from 10 - 20 cmH20 at mid-exhalation
-used for 15-20 mins 3-4x/day
-improve secretion expectoration, reduce RV (decrease hyperinflation) and improve
airway maintenance (CF, pneumonia)
-discontinue if sinusitis, epistaxis or ear infection occurs
-inspire larger than normal VT and exhale actively but NOT forcefully. exhalation 2-3x
longer than inspiration

✔✔Autogenic Drainage - ✔✔-primarily for CF and bronchiectasis
-breathe at low lung volumes to loosen secretions from the small airways
-helps to accumulate secretions in the middle airways
-during the last stage the patient breathes at high lung volumes

✔✔Intrapulmonary Percussive Ventilation - ✔✔-Combination of high frequency pulse
delivery (100-250 cycles/min of a sub-tidal colume and a dense aerosol
-percussive effect of gas delivery improves ventilation past obstructions in the airway
thereby delivering more aerosol to the distal airways.
-Dense aerosol delivery promotes bronchial hygiene, reduces edema, and relieves
bronchospasm with the appropriate medications
-starting source pressure is 30 psi

✔✔Discontinuing bronchial hygiene - ✔✔-clear breath sounds and x-ray
-ambulating well
-strong cough
-afebrile for 24 hours
-hazards occur (dizziness, SOB, cyanosis, etc.)

,✔✔iatrogenic hypoxemia - ✔✔induced by a physician's words or therapy (used
especially of a complication resulting from treatment)

can be caused by suctioning

✔✔Suction Pressures - ✔✔Adult: 100 - 120 mm Hg
Child: 80 - 100 mm Hg
Infant: 60 - 80 mm Hg

✔✔Coude tip catheter - ✔✔suction catheter angles to help suction the LEFT main stem
bronchus

✔✔Closed system/inline suction catheter (Ballard) - ✔✔-allows patient to recieve
ventilation and oxygenation during suctioning
-for pt with high oxygen/PEEP requirements, pulmonary infections, frequent suctioning
and hemodynamic instability

✔✔Catheter sizes - ✔✔-ideal length is 20 - 22 inches
-external diameter of the suction catheter should be no greater than 1/2 the inside
diameter of ET/trach tube

✔✔Lukens trap/sterile suction trap - ✔✔-collect sputum specimen
-placed in an upright position between the suction catheter and the suction tubing
-flush catheter with sterile water or isotonic saline
-saline for cytology samples

✔✔Change size and type of catheter if - ✔✔-difficulty removing secretions (verify
appropriate size for airway)
-change to Coude Catheter for LEFT main stem bronchus
-change to closed system if pt has an infection, PEEP, or frequent desaturation

✔✔Altering negative pressure - ✔✔-increase negative pressure to remove thick
tenacious secretions
-do not exceed appropriate pressures

✔✔Instill irrigating solutions - ✔✔-5-10 mL of normal saline to dilute secretions too thick
to aspirate
-5-10 mL of 10% solution of Acetylcysteine (Mucomyst) can be used for thick tenacious
secretions + bronchodilator

✔✔Troubleshooting Suctioning procedure - ✔✔-check catheter for patency
-assure vacuum is working/appropriate pressure
-change or empty a full collection bottle
-check all connections

, ✔✔Bubble humidiifier - ✔✔-incorporates pressure pop-pff valves set at 2 psig/40 mm
Hg
-check by occluding or pinching the connection tubing and listen for whistling sound
-if no sound = leak

✔✔Troubleshooting bubble humidifiers - ✔✔-efficiency depends of water level in the
reservoir = replace or refill if non disposable
-if whistling = flow too high or obstructed tubing

✔✔Passover or blow-by humidifer - ✔✔-evaporation occurs as gas passes over the
water container/reservoir
-least effective in humidifying an artificial airway unless heated
-commonly used in conjunction with infant ventilators and circuits

✔✔Heat Moisture Exchanger (HME) - ✔✔-should be located in the vent circuit between
the wye and the patient (where deadspace is located)
-creates a small VD
-can cause increased delivery pressure = replace HME
-removed during aerosol therapy
-not as effective as humidifiers and increase/thicken secretions = change to heated
humidifiers

✔✔Wick Humidifers - ✔✔-can deliver 100% body humidity (44mg/L)
-low risk of cross contamination (nosocomial infection) because no particles are being
produced
-for vents, CPAP, etc

✔✔Heated Wire Circuits - ✔✔-minimizes circuit condensation
-wire like structure inside the vent circuit to maintain a set gas temperature thru the
entire circuit
-can be both limbs or just inspiratory limb

✔✔Jet Nebulizers - ✔✔-utilize Bernoulli's principle to create an aerosol then encounter
a baffle
-creates particles within therapeutic size range (1-10 microns)

✔✔HHN/SVN - ✔✔-1 to 3 second breath hold is important to enhance medication
delivery
-sputtering sounds indicates that all of the solution has been nebulized

✔✔Large Volume Nebulizers - ✔✔-deliver bland aerosol to upper airway
-output: 1-2 mL/min
-heating element for thick secretions
-FiO2 decreased = air entrainment is increased. lower mist density, total flow or mist
output increases (vice-versa)

Información del documento

Subido en
19 de julio de 2026
Número de páginas
22
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK
3.5
(40)
Vendido
278
Seguidores
10
Artículos
32861
Última venta
3 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes