Questions with Correct Answers Graded
A+
November 14, 1994 - What date was the sale of CFC's & HCFC's restricted to
technicians certified in refrigerant recovery?
Memorize it, ya'll. - 1987-
Montreal Protocol
July 1 1992-
Violation to vent CFCs or HCFCs
Nov 15 1993-
Recovery/Recycling equipment must be certified and labeled by EPA
AND
Before this date recovery equipment needed to be capable of removing 80% of the
refrigerant, w or wo compressor, or 4 in Hg
After this date recovery equipment needs to be capable of removing 90%, or 80%
without working compressor, or 4 in Hg
AND
Required level of evacuation for Low Pressure appliances before this date was 25
inches Hg, after this date 25 mm Hg
Nov 14 1994-
Certification needed to service, maintain, or dispose of appliances with refrigerants AND
Sale of CFC and HCFC refrigerants restricted to certified techs
Nov 15 1995-
Violation to vent HFCs
Dec 31 1995-
CFCs no longer produced
15% - Comfort cooling appliances containing more than 50 lbs of refrigerant must be
repaired when the annual leak rate exceeds %
35% - Commercial and Industrial process refrigeration containing ore than 50 lbs of
refrigerant must be repaired when the annual leak rate exceeds %
00
4 10
4 10
,4 15
0 0 - Required Recovery Levels for Type II appliances, before and after 11/15/93:
HCFC22 less than 200 lbs = B4-0 After-0
HCFC22 more than 200 lbs= B4-4 After-10
NonHCFC22 less than 200 lbs= B4-4 After 10
NonHCFC22 more than 200 lbs= B4 4 After 15
Very high pressure appliances= B4-0 After-0
Recover all refrigerants. - Section 608 of the Federal Clean Air Act requires technicians
to what?
The earth's stratosphere. - The objective of the Clean Air Act is to protect what?
HydroFlouroCarbon's - HFC's
ChloroFluoroCarbon's - CFC's
Ozone Depletion Potential - ODP
The Montreal Protocol. - Which international treaty agreement was the basis for Section
608?
1. Crop losses
2. Increases in eye diseases
3. Skin Cancer
4. Reduced marine life
5.Deforestation
6.Increased ground level ozone - Depletion of the ozone in the stratosphere is known to
cause what 6 things?
These atoms attack Ozone Molecules causing the formation of Chlorine Monoxide
(CLO), after colliding with another Ozone Molecule, causes 2 Oxygen (O2) molecules to
be made & leaving an atom of chlorine to act as "Free Agent" starting the process over
until 100,000 molecules of Ozone are destroyed by just one atom of chloride. - What
happens when CFC or HCFC molecules get in the stratosphere & free atoms of
Chlorine are set free?
November 15, 1993 - What date was recovery equipment required to be certified by a
lab, & achieve higher evacuation levels, & have low loss fittings?
November 14, 1994 - On what date was technician certification required?
December 31, 1995 - What date were CFC's phased out of production?
, Persons who maintain, service, repair, or dispose of small appliances (containing 5
pounds of refrigerant (or less). - What is EPA 608 Type I certification?
Persons who maintain, service, repair, or dispose of high and very high pressure
appliances. Except small appliances and motor vehicle air conditioning systems. - What
is EPA 608 Type II certification?
Persons who maintain, service, repair, or dispose of low pressure appliances. - What is
EPA 608 Type III certification?
Persons who maintain, service, repair, or dispose of both low and high pressure
equipment, as well as appliances. - What is EPA 608 Universal certification?
HydroChloroFluoroCarbons - HCFC's
Commonly known as HCFC's, they are a group of man-made compunds containing
hydrogen, chlorine, fluorine, and carbon. - What are HydroChloroFluoroCarbons?
80% - A recovery cylinder must not be filled more than % of it's capacity by weight?
Up-right with proper DOT classification tags. - How should refrigerant cylinders be
shipped?
Polyolester - What oil MUST be used with ALL HFC's for HVAC/Refrigeration but will
also work with CFC's and HCFC's.
Trillion - HCFC's have very low atmospheric concentrations measured in parts per?
15% - All cooling systems containing more than 50 lbs. of refrigerant must be repaired
when the annual leak rate exceeds ?
All CFC's - Mineral Oils are used with?
HCFC's (Will also work with CFC's) - Alkebenzene is used alone or as an additive for?
Polyolester - POE
A small appliance that is manufactured, charged, and hermetically sealed in a factory
with 5 lbs. of refrigerant or less. - What is the definition of a Type I Appliance?
High pressure or very high pressure appliances except for small appliances and motor
vehicle air conditioning. Refrigeration systems containing more than 5 Lbs. of high or
very high pressure refrigerants. - What is the definition of a Type II Appliance?
Low pressure equipment like low pressure chillers. - What is the definition of a Type III
Appliance?