Radio waves, light, and x-rays are all examples of

energy. - (ANSWER)Electromagnetic



Which of the following is the most effective means of protecting the radiographer from exposure to
radiation? - (ANSWER)Increase distance



The main reason to avoid repeat radiographs is the: - (ANSWER)patient received unnecessary radiation



During portable X-ray examinations, the technologist's best protection is: - (ANSWER)distance



During fluoroscopy the personal radiation badge should be worn - (ANSWER)Outside the lead apron at
the collar



The greater the distance between the x-ray tube and the radiographer, the less the radiation exposure
the radiographer receives. - (ANSWER)True



Personal dosimeters are designed to be worn: - (ANSWER)outside the lead apron near the neck



The biggest source of man-made ionizing radiation exposure to the public is - (ANSWER)diagnostic x-rays



The basis for the NCRP policies and regulations for personnel and patients is the: - (ANSWER)ALARA (as
low as reasonably possible)



A stable atom has the same number of protons and

-_____ contained in the nucleus. - (ANSWER)neutrons



Lead aprons, lead gloves and thyroid shields are all types of - (ANSWER)Radiation protective equipment

,RADT Final Exams Questions with 100% Correct Answers | Verified |
Updated (Actual Exam) LATEST VERSION!!




Good techniques to reduce repeat radiographs include accurate positioning and accurate exposure
factors. - (ANSWER)True



This council sets the dose limits for radiation workers: - (ANSWER)National Council on Radiation
Protection and Measurements



The best place to store your radiation dosimeter when not on duty is: - (ANSWER)in an area of work that
does not receive any radiation.



The law of Bergonié and Tribondeau implies that radiosensitivity is greatest in: - (ANSWER)cells that are
rapidly dividing, (young bodies)



Contrast can be defined as: - (ANSWER)The difference in density between light and dark areas of an
image



Arthrograms are performed to visualize which of the following areas? - (ANSWER)Joints



Contrast is considered: - (ANSWER)The difference in densities in a image



Myelography is being replaced by which imaging modality? - (ANSWER)MRI



The conversion of energy that produces X-rays is a result of

____ striking the_____ - (ANSWER)Elections;anode



The positively charged terminal in an x-ray tube is the: - (ANSWER)Anode

, RADT Final Exams Questions with 100% Correct Answers | Verified |
Updated (Actual Exam) LATEST VERSION!!




External preparation of the patient for a radiographic examination is the primary responsibility of : -
(ANSWER)The radiographer



CT is considered a low-dose procedure T/F - (ANSWER)False



When the mAs setting on the control panel of an x-ray generator is increased, the radiograph: -
(ANSWER)becomes darker



Which one of the following imaging modalities use sound to see? - (ANSWER)Sonography



The two active components of an x-ray tube are: - (ANSWER)a negative cathode and a positive

anode



The sharpness of structural lines in an image is called: - (ANSWER)spatial resolution



What are the two main parts of the X-ray tube? - (ANSWER)Anode and cathode



Projectile electrons travel from___ to ___ - (ANSWER)Cathode to anode



Density is controlled by: - (ANSWER)mAs



kVp is adjusted to control the: (3 things) - (ANSWER)Radiographic contrast

energy of the beam

penetrating quality of the beam



Imaging equipment that allows for the manipulation of the image after exposure is called what? -
(ANSWER)Digital Imaging

Información del documento

Subido en
13 de julio de 2026
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$21.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AlphaDocs
5.0
(498)
Vendido
2183
Seguidores
8
Artículos
587
Última venta
3 días hace

Reseñas de compradores verificados



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes