Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 6 páginas
Examen

Tradesman Exam Written Portion LATEST EDITION 2026 ACTUAL PASSING IS GUARANTEED !

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

Tradesman Exam Written Portion LATEST EDITION 2026 ACTUAL PASSING IS GUARANTEED !

Vista previa del contenido

Tradesman Exam Written Portion LATEST EDITION
2026 ACTUAL PASSING IS GUARANTEED !



Overflows, if on a fixture, must drain to inlet (fixture) side of trap. - ANSWER☑️⭐-True



Drainage pipe shall be tested with a 15 foot of head of water or air at 25 psi. - ANSWER☑️⭐-False



Fixtures must not be made of approved, smooth impervious material. - ANSWER☑️⭐-False



A 4" X 3" water closet bend is acceptable. - ANSWER☑️⭐-True



The owner or owners' agent is responsible for maintaining the plumbing system in a safe condition. -
ANSWER☑️⭐-True



Water closets shall be set no closer than 30 inches center to center of 15 inches from a side wall. -
ANSWER☑️⭐-True



Showers must be at least 36 inches inside diameter - ANSWER☑️⭐-False



Water closets screws and bolts shall be zinc. - ANSWER☑️⭐-False



Access must be provided to slip-joint connections. - ANSWER☑️⭐-True



Copper must be supported horizontally - 6 feet of closer on small pipe and 10 feet on 1-1/2" or larger
pipe. - ANSWER☑️⭐-True

, Vents shall terminate at least ______________ horizontally or 3 feet above all openable doors and
windows. - ANSWER☑️⭐-10 feet



Hub and spigot joints in cast iron are made with __________ or hemp and lead. - ANSWER☑️⭐-Oakum



Drill, tapped or ____________ joints are prohibited. - ANSWER☑️⭐-Saddle type



Change of direction from vertical to horizontal must be made with _______________ fittings. -
ANSWER☑️⭐-Long turn



________________ shall be used to seal the vent water tight where it passes through the roof. -
ANSWER☑️⭐-Flashing



Vents must rise vertically to ___________ above the flood level rim of the highest fixture served before
turning horizontally. - ANSWER☑️⭐-6 inches



The vertical distance cannot be over ____________ from the outlet of the fixture to the trap weir. -
ANSWER☑️⭐-24 inches



______________ are prohibited. - ANSWER☑️⭐-Crown vents



____________________ shall be graded back to drainage pipe at the fixture it serves. - ANSWER☑️⭐-
Vents



Trap seals must maintain from _________________ of water. - ANSWER☑️⭐-2 to 4 inches



A ________________ shall connect above the weir of the fixture trap. - ANSWER☑️⭐-Fixture vent



Clean out plugs shall be made of _________ or plastic. - ANSWER☑️⭐-Brass

Información del documento

Subido en
11 de julio de 2026
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$22.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
angiengari
5.0
(1)
Vendido
1
Seguidores
0
Artículos
258
Última venta
3 semanas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes