✔✔A designated Hot Work area must be at least_______ feet away from combustible
materials. - ✔✔35.

✔✔For all Hot Work, inspections must be completed_______ after completion of torch
operations. - ✔✔30 minutes.

✔✔A minimum ___________ rating Fire Extinguisher must be readily accessible within
________ of the hot work location for torch operations. - ✔✔2-A:20-B:C, 30 feet.

✔✔For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher
must be readily accessible within ________. - ✔✔3-A: 40-B:C, 30 feet.

✔✔Empty compressed gas cylinders - ✔✔Should be handled in the same manner as
full ones.

✔✔Panic Bar - ✔✔A device fitted on the inside of a door that would allow a person to
push against a door to open it.

✔✔A type of valve typically used in sprinkler systems - ✔✔OS & Y Valve- Outside
Screw and Yoke Valve.

✔✔Fire Drill - ✔✔A training exercise by which building occupants are familiarized with
and/ or practice the procedures for the safe, orderly and expeditious in-building
relocation, partial evacuation or evacuation, as applicable to the occupancy or building
type, in accordance with the fire safety and evacuation plan.

✔✔shall not be considered a fire - ✔✔flame used in any lawful, properly operating
device, equipment or system or other controlled setting.

, ✔✔Fire Watch - ✔✔A temporary measure intended to ensure continuous and
systematic surveillance of a building or portion thereof by one or more qualified
individuals for the purposes of identifying and controlling fire hazards, detecting early
signs of fire, raising an alarm of fire and notifying the department.

✔✔Hot Work - ✔✔Cutting, welding, thermit welding, brazing, soldering, grinding,
thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any
other similar operation or activity.

✔✔Torch Applied Roof-System - ✔✔Bituminous roofing systems using membranes that
are adhered by heating with a torch and melting asphalt back coating instead of
mopping hot asphalt for adhesion.

✔✔Egress - ✔✔A means of exit from a fire or other emergency.

✔✔Single Action fire alarm pull station - ✔✔requires the user to simply pull a lever or
break glass to activate the alarm. This type is commonly used indoors.

✔✔Double Action fire alarm pull station - ✔✔Double Action fire alarm pull station-
requires the user to take two steps in order to activate the alarm such as lifting a cover
and then pulling a lever. This type of alarm is commonly used outside.

✔✔All gas containers and the related equipment - ✔✔must be protected from extreme
temperature and physical damage.

✔✔Any single standard portable LPG container must not exceed - ✔✔100 lbs in weight.

✔✔Any single CNG container must not exceed - ✔✔381 SCF.

✔✔Permits shall be readily available on the premise for inspection by - ✔✔Fire
Department representatives.

✔✔NFPA stands for - ✔✔National Fire Protection Association.

✔✔Most common fuel gases used in blowtorches are - ✔✔LPG (e.g. butane, propane),
natural gas (methane) (either CNG or piped natural gas).

✔✔A fire guard is responsible for - ✔✔overseeing torch operations.

✔✔The pre-hot work check must be conducted by - ✔✔the responsible person before
hot work is authorized and at least once per day.

✔✔The check reports must be kept at the work site - ✔✔maintained on the premises for
a minimum of 48 hours after work is complete.

Información del documento

Subido en
11 de julio de 2026
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$16.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXAMCAFE
3.2
(17)
Vendido
147
Seguidores
6
Artículos
26087
Última venta
2 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes