Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

MED GAS UPDATED ACTUAL QUESTIONS AND CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
48
Grado
A+
Subido en
07-07-2026
Escrito en
2025/2026

MED GAS UPDATED ACTUAL QUESTIONS AND CORRECT ANSWERS

Institución
MED GAS
Grado
MED GAS

Vista previa del contenido

MED GAS UPDATED ACTUAL QUESTIONS
AND CORRECT ANSWERS

●● In those portions of systems intended to handle oxygen at pressures
greater than 350 psi the interconnecting hose shall NOT contain
________ materials?
Answer: Polymeric


●● In a Category 1 Dental and Gas Vacuum Piping system, which of the
following is an NFPA 99 requirement for the labeling of pipes?
Answer: Color coding & non-standard pressure


●● Which of the following treatments shall be performed before brazing
cut ends of a tube to be installed in a medical gas piping system?
Answer: Cut ends shall be rolled smooth or deburred


●● Manifolds for gas cylinders shall actuate a(an) _______ signal and
shall activate an indicator at all _______ alarm panels to indicate when
or just before changeover from one header to the other.
Answer: Local, master


●● In a non-anesthetizing area, on which side of a zone valve shall the
pressure/vacuum sensor be located?

,Answer: Station outlet/inlet


●● What is the purpose of using an oxygen analyzer during the piping
purge prior to brazing?
Answer: Assure that all ambient air has been removed from the pipeline


●● A medical gas master or area alarm panel shall be set to actuate a(an)
_____ indicator when the communication with an alarm-initiating device
is disconnected.
Answer: Audible and visual


●● When an EOSC becomes the temporary supply source, a facility will
monitor the system by use of which of the following?
Answer: Providing four connection points to both master alarms


●● Which of the following conditions must be met where medical gas
and vacuum systems are installed by non-certified personnel?
Answer: installation by anyone other than 6010 certified personnel is
NOT permitted


●● Which of the following systems shall NOT be permitted to be
located in an outdoor enclosure?
Answer: Medical air compressor supply sources

,●● Metallic flexible joints are being used in the pipeline for vibration
control. Which of the following is NOT required of such joints?
Answer: suitable for service at 150 psig or above


●● who shall witness the installer-performed standing vacuum test?
Answer: the authority having jurisdiction, or its designee


●● the medical air compressor intake shall be located a minimum of
how many feet from any exhaust or plumbing vents?
Answer: 25 feet


●● the gas produced by evaporation from the secondary header in a
cryogenic liquid cylinder system shall enter the supply system ________
of the final line regulator.
Answer: upstream


●● with the approval of the Authority Having Jurisdiction, in which
areas shall the zone valves be permitted to be secured to prevent
inappropriate access?
Answer: pediatric


●● factory installed inlet tubes on station outlets shall be NOT less than
__________with 0.3 inch minimum inside diameter.
Answer: NPS 1/4, 3/8 in. O.D.

, ●● which of these operations would not breach the vacuum system?
Answer: testing a system component with a leak detector solution


●● except for valves in zone valve boxes, all valves shall be located in
secured areas such as locked pipe chases, or be __________.
Answer: latched or locked in operation position


●● medical gas Central Supply systems are NOT permitted to be located
where?
Answer: in an unlocked location


●● fittings, valves, and other components for field-installed positive
pressure distribution systems shall be ________ until prepared for
installation.
Answer: delivered sealed, labeled, and kept sealed


●● vacuum piping for __________ shall be connected separately from
the medical surgical system directly to the receiver tank through its own
isolation valve and fluid trap located at the receiver.
Answer: a teaching laboratory


●● NFPA 99 specifies that the medical gas piping system shall be
protected against all EXCEPT which of the following?

Escuela, estudio y materia

Institución
MED GAS
Grado
MED GAS

Información del documento

Subido en
7 de julio de 2026
Número de páginas
48
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Favorgrades Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
820
Miembro desde
3 año
Número de seguidores
376
Documentos
46573
Última venta
2 días hace
Favorgrades Emporium

3.8

193 reseñas

5
81
4
44
3
33
2
11
1
24

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes