1. The primary purpose of the National Electrical Code (NEC) is to:
A. Provide a design manual for electrical systems
B. Establish minimum requirements for electrical safety
C. Reduce installation costs
D. Replace local building codes
The NEC establishes minimum requirements for practical safeguarding of persons
and property from electrical hazards.
2. Which conductor is intentionally grounded under normal operating
conditions?
A. Equipment grounding conductor
B. Bonding jumper
C. Grounded conductor
D. Grounding electrode conductor
The grounded (neutral) conductor is intentionally connected to ground as part of
the electrical system.
3. A branch circuit is defined as the circuit conductors between:
A. Utility transformer and service disconnect
, B. Meter and panelboard
C. Service equipment and feeder
D. Final overcurrent device and the outlets
The NEC defines a branch circuit as extending from the final overcurrent protective
device to the outlets.
4. The interrupting rating of equipment must be:
A. Equal to the load current
B. Less than the available fault current
C. Optional if current limiting fuses are installed
D. Not less than the available fault current
Equipment must safely interrupt the maximum available fault current.
5. A conductor termination marked for 75°C insulation may be used:
A. Only with 60°C conductors
B. With conductors rated 75°C or higher, using the 75°C ampacity
C. With any conductor regardless of rating
D. Only with aluminum conductors
The termination rating determines which ampacity column applies.
6. Which type of overcurrent device protects against overloads and short
circuits?
A. Disconnect switch
B. Ground rod
C. Circuit breaker
D. Junction box
Circuit breakers provide overcurrent protection for both overloads and short
circuits.
7. Service conductors terminate at the:
A. Branch circuit panel
B. Motor controller
, C. Transformer secondary
D. Service equipment
Service conductors end at the service disconnecting means.
8. The minimum cover for Schedule 80 PVC under a residential driveway is
determined by:
A. Local utility
B. Manufacturer instructions
C. NEC burial requirements
D. Property owner preference
The NEC specifies minimum cover requirements for underground wiring methods.
9. The grounding electrode conductor connects the:
A. Neutral to branch circuits
B. Equipment grounding conductor to receptacles
C. Grounded service conductor to the grounding electrode system
D. Feeder to transformer
Its purpose is to connect the service to the grounding electrode system.
10.Bonding is intended to:
A. Increase voltage
B. Reduce conductor size
C. Ensure electrical continuity and fault current path
D. Prevent overloads
Bonding creates an effective ground-fault current path.
11.Which wiring method is permitted in exposed locations subject to physical
damage?
A. NM cable
B. Flexible cord
C. Rigid Metal Conduit (RMC)
D. Lamp cord
Rigid Metal Conduit provides excellent mechanical protection.