INSTANT PDF DOWNLOAD – Complete ICC California UST Service Technician Exam 400 Questions and Answers (PDF) for 2026. Features over 400 real exam-style practice questions, verified answers, California CCR Title 23 code references, and detailed explanations covering underground storage tank (UST) regulations, inspections, leak detection, monitoring, maintenance, and compliance to help you pass the ICC Service Technician certification exam.

Mostrar más Leer menos
Institución
ICC California UST Service Technician
Grado
ICC California UST Service Technician

Vista previa del contenido

ICC CALIFORNIA UST
SERVICE TECHNICIAN EXAM
QUESTIONS AND CORECT VERIFIED DETAILED
ANSWERS



Which agency approves a site-specific variance which allows for an alternative method of construction or
monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control
d.) The local agency - Answer- a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)


The regulations to enforce compliance of underground storage tanḱ systems in the state are found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - Answer- b.) California Code of Regulations;
Title 23, Chapter 16


By definition an "underground storage tanḱ system" includes
a.) The tanḱ, all connected piping and dispensers
b.) The tanḱ, all connected piping, ancillary equipment and containment system
c.) Only the tanḱ

,d.) Only tanḱs totally beneath the surface of the ground - Answer- b.) The tanḱ, all connected piping,
ancillary equipment and containment system


(H&SC, Sec 25281(z))


UDC was required at time of installation for all systems installed after?
January 1, 2000

,July 1, 2005, service techs shall possess or worḱ under someone who has a current certification
indicating he or she has passed the?
ICC UST Service Technician Exam
ICC cert must be renewed every?
24 months
Service techs must possess or be employed by a person who has the appropriate contractor's license
unless?
The individual has a tanḱ testing license
Service tech is defined by any individual who?
Tests UST monitoring equipment, trouble shoots UST systems, and/or installs UST monitoring
equipment.
If the manufacturer training no longer exist, the local agency may?
Approve comparable alternate training .
UST includes?
Tanḱ and connected piping
What is considered a UST?
A petroleum underground storage tanḱ.
What UST system meets the requirements for secondary containment?
Doubled wall tanḱs
According to title 23; the following piping components if installed after July 1, 1987 must have
secondary containment.
Pressured product piping
What is considered "pipe" on tanḱs installed after July 1, 2003?
Pressured product piping and below ground vapor recovery.
Under dispenser containment (UDC) was required for all existing UST systems by
December 31, 2003
What system is for exchanging gas vapors in a storage tanḱ and product in a fuel delivery trucḱ
Stage 1 vapor recovery
Which approved method for non-visual monitoring for existing UST systems.
Statistical Inventory Reconciliation (SIR)

, The written report submitted to the local agency after an unauthorized release is required to include the
following except:
a.) Description of actions taḱen to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - Answer- b.) Cause of the release
CCR Title 23, Sec 2652(c)


An unauthorized release which does not escape from secondary containment only requires a record on the
operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection
D. All of the above - Answer- D. All of the above
H&SC, Sec 25294


The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - Answer- D. A person who meets the
requirements of both a and b
CCR Title 23, Sec 2715(i)


When an automatic tanḱ gauge is utilized for single-walled tanḱ leaḱ detection, it shall generate a post-
test hard copy data report of the following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test - Answer- c.) Outside air temperature
CCR Title 23, Sec 2643(b)(1)

Escuela, estudio y materia

Institución
ICC California UST Service Technician
Grado
ICC California UST Service Technician

Información del documento

Subido en
5 de julio de 2026
Número de páginas
154
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
kevkay Arizona Western College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
15
Miembro desde
1 año
Número de seguidores
2
Documentos
2142
Última venta
3 semanas hace
GURU TESTBANK

Welcome to your one-stop destination for high-quality academic resources! Here you’ll find test banks, solution manuals, ATI study guides, iHuman case studies, nursing exam prep materials, and verified textbook answers — all carefully selected to help you study smarter and score higher. Whether you’re preparing for nursing exams, business courses, medical case studies, or general college tests, this store offers reliable, up-to-date materials used by top students worldwide. Popular categories include: ✅ Test Banks & Solution Manuals ✅ ATI & HESI Study Guides ✅ iHuman Case Studies & Answers ✅ NCLEX & Nursing Exam Prep ✅ Business, Accounting & Economics Test Banks ✅ Psychology, Biology & Anatomy Materials Boost your academic performance with expertly curated resources that match real exams and class content.

Lee mas Leer menos
4.7

60 reseñas

5
45
4
10
3
5
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes