DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW!!
According to the IBC, the "blank" is to hire the special inspector. -CORRECT ANSWER-owner
or owners agent. 2009 IBC Section 1704.1
According to the IBC, the "blank" is the responsible for the approval of a person's
qualifications to act as a special inspector. -CORRECT ANSWER-code official. 2009 IBC,
Section 1704.1
According to the IBC, discrepancy corrections are made known to the building official by: -
CORRECT ANSWER-final report. 2009 IBC, Section1704.1.2
When is the code official to be made aware of a discrepancy found during a special
inspection? -CORRECT ANSWER-If it is not corrected by the contractor. 2009 IBC, Section
1704.1.2
According to the Model Program for Special Inspection, the special inspector is to document
work that is nonconforming: -CORRECT ANSWER-In a written report - Section II B 4 - Model
Programs
According to the Model Program for Special Inspection, the special inspector is to prepare
written report of inspection: -CORRECT ANSWER-After each inspection visit - Section II B 5 -
Model Programs
,According to the Model Program for Special Inspection, which of the following items does
not need to be included in each inspection report? -CORRECT ANSWER-Description of
discussions with the contractor - Section B 5 - Model Programs
According to the Specification for Structural Joints using high strength bolts, the nominal
diameter of standard bolt holes shall be how much larger than the nominal bolt diameter? -
CORRECT ANSWER-1/16 inch - Specification for Structural Joints Table 3.1
Discrepancies in the work shall be brought to the immediate attention of the "blank" for
corrective action. -CORRECT ANSWER-the contractor - 2009 IBC, Section 1704.1.2.
The special inspector shall furnish inspection reports to the "blank" and to the "blank"? -
CORRECT ANSWER-Building Official and Registered Design professional
The special inspector shall provide continuos inspection of: -CORRECT ANSWER-Single-pass
fillet welds greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item 5.3
The special inspections required by this code are not required where the work is done on
the premise of a? -CORRECT ANSWER-Approved fabricator - 2009 IBC, Section 1704.2.2
The special inspection of the steel fabrication process shall not be required where the
fabricator does not perform any? -CORRECT ANSWER-heating operations - 2009 IBC, Section
1704.3, Exceptions # 1
According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be
used for the material test for steel sheets. -CORRECT ANSWER-A568 - Section A31,
Specifications for Structural Steel Buildings
According to the Specifications for Structural Steel Buildings, the "blank" conducts the
material tests for identification of the structural steel. -CORRECT ANSWER-Fabricator or
Testing Laboratory - Section A31, Specifications for Structural Steel Buildings.
, According to the Specifications for Structural Steel Buildings, which of the following steel
members are allowed to be unidentified steel? -CORRECT ANSWER-Unimportant members,
where their physical properties and weldability would not affect the structure strength -
Section A31b, Specifications for Structural Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of
special material to be identified? -CORRECT ANSWER-It is marked by the supplier - Section
5.1.1, Code of Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how are
fabricators stock steel material identified? -CORRECT ANSWER-Certified mill test reports -
Section 5.2.2 - Code of Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, what ASTM Standard would
apply to a sample for structural steel pipe? -CORRECT ANSWER-A53 - Section A31a -
Specification for Structural Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, the number of
samples required to be tested for structural steel is: -CORRECT ANSWER-The number
specified by the ASTM specification - Section 5.1.1 - Code of Standard Practice for Steel
Buildings and Bridges
According to the Specification for Structural Steel Buildings, which ASTM standard would
apply to a sample for structural steel plates? -CORRECT ANSWER-A36, A283, and A242 -
Section A31a - Specification for Structural Steel Buildings
According to the Specification for Structural Steel Buildings, "blank" tests are required for
samples for built-up sections consisting of plates over 2 inches in thickness. -CORRECT
ANSWER-Charpy V-notch testing - Section A31d, Specification for Structural Steel Buildings
According to the Specification for Structural Steel Buildings, ASTM standard "blank" would
apply to a sample for structural steel bars. -CORRECT ANSWER-A36, A529, and A572 -
Specification for Structural Steel Buildings