Standard for testing ability of exterior vents to resist ember entry -
ANSWER ✔✔ASTM E2886
At minimum every building shall be provided with a water supply meeting
requirements of _______________________________. - ANSWER
✔✔NFPA 1142 Standard for Water Supplies for Suburban and Rural Fire
Fighting
, Wildland Fire Mitigation activities fall into what 3 broad categories? -
ANSWER ✔✔1) Education
2) Engineering
3) Enforcement
Steepest allowable road grade (without other mitigation measures
agreed on by AHJ) - ANSWER ✔✔10%
Which NFPA standard provides minimum requirements to fire protection
organizations on the management of wildland fire, including prevention,
mitigation, preparation and suppression? - ANSWER ✔✔NFPA 1143
Standard for Wildland Fire Management
Exterior doors shall be - ANSWER ✔✔Solid-core wood no less than 1
3/4 inch thick
approved non-combustible material
or have a minimum 20 min fire rating
Vertical clearance for roadways and unobstructed width - ANSWER
✔✔13 ft 6 inch vertical
Unobstructed width of 20ft