What safety device cuts off fuel supply in the event of loss of ignition? correct answers Flame
scanner-Fire eye


A flame failure cutout automatically: correct answers Breaks the cycle on a flame-out


Where do you find a cyclone separator? correct answers Steam drum


What chemicals will prevent oxidation of drum and tubes? correct answers Sodium sulfite and
Hydrazine


Failure of what device causes a furnace explosion? correct answers Fan failure or purge failure


What would one standard atmosphere at 14.7 psi be in feet of water? correct answers 34 feet


How often do you test a low water cut-off? correct answers Daily, by blowing down the column


A flue gas analysis is done to: correct answers Determine combustion efficiency


How often are boilers inspected? correct answers Annually


What auxiliary would improve boiler efficiency? correct answers Economizer


If a baffle breaks, what happens? correct answers Increase of furnace gases & stack temperature


Why are baffles used in steam drums of water tube boilers? correct answers To direct the flow of
gasses

, What device measures draft? correct answers Manometer


A manometer is calibrated in: correct answers Inches of water


What type of cycle is the simple power plant cycle? correct answers The Rankine Cycle


What is required for complete combustion? correct answers Mixture, atomization, temperature,
time (MATT)


The main purpose of testing a safety valve is to: correct answers Make sure valve operates freely


When testing a safety valve by hand, you must: correct answers Have at least 75% of popping
pressure


What is the absolute pressure of a 180 psi boiler? correct answers 194.7psia (add 14.7)


How many furnace volume air changes should occur during purge? correct answers 4


What valve must be between boiler and safety valve? correct answers No valve


What is total force of Safety valve with a 2 1/2 inch disc at 30 pounds pressure? correct answers
2.5 × 2.5 × .7854 × 30= 147psi


How do you clean fire tube boilers? correct answers Wire brushes


Water hammer can cause: correct answers Steam pipe failure

Información del documento

Subido en
1 de julio de 2026
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.79

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Quillan
4.6
(5)
Vendido
51
Seguidores
27
Artículos
3636
Última venta
2 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes