Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not
smaller than No. ______________ AWG. - ANSWERS-12 AWG.



2015 IRC Section E4202.2 Flexible cords, Item 1



Receptacles shall be installed so that no point along the floor line in any wall space is more than
_________ feet, measured horizontally, from an outlet in that space. - ANSWERS-6 Feet.



This is the rule 6/12 rule: 6 feet from any door opening and every 12 feet after that, measure along the
wall.



2015 IRC Section E3901.2.1 Spacing.



Receptacles installed on 15- and 20-ampere-rated branch circuits shall be of the ___________ type. -
ANSWERS-grounding.



2015 IRC Section E4002.2 Grounding type.



In clothes closets, surface-mounted incandescent luminaires shall have _________ inches minimum
clearance from the nearest point of storage space. - ANSWERS-12 inches.



This is measured horizontally and changes to 6 inches for surface mounted/recessed fluorescent and
recessed incandescent fixtures.



2015 IRC Section E4003.12 Luminaries in clothes closets, Item 1

,Conductors in NM cable assemblies shall be rated at _________ Celsius. - ANSWERS-90 degrees Celsius.



The 90 degree Celsius rating shall be permitted to be used for ampacity correction and adjustment
purpose provided that the final corrected or adjusted ampacity does not exceed that for a 60 degree
Celsius rated conductor.



2015 IRC Section E3705.4.4 Conductors of Type NM cable.



In calculating box fill, each No. 12 AWG conductor shall require ______________ cubic inches free space
within the box. - ANSWERS-2.25 cubic inches.



2015 IRC Table E3905.12.2.1 Volume Allowance Required Per Conductor.



Except for Type IC luminaires, thermal insulation shall not be installed above a recessed luminaire or
within _______________ inches of the recessed luminaire's enclosure. - ANSWERS-3 inches.



Exception for Type IC luminaires.




2015 IRC Section E4004.9 Recessed luminaire installation.



Branch circuit ratings for space-heating and water-heating appliances shall be considered ____________
loads. - ANSWERS-continuous.



2015 IRC Section E3702.10 Branch circuits serving heating loads.



A minimum of ____________ 20-ampere-rated branch circuits shall be provided to serve all wall and
floor receptacle outlets located in the kitchen, pantry, breakfast area, dining area or similar area of a
dwelling. - ANSWERS-Two.

, 2015 IRC Section E3703.2 Kitchen and dining area receptacles.



A minimum of one ____________-ampere-rated branch circuit shall be provided for receptacles located
in the laundry area and shall serve only receptacle outlets in the laundry area. - ANSWERS-20 ampere.



Receptacles for appliances like the washer shall be located within 6 feet of the appliance location. See
Section E3901.5



2015 IRC Section E3703.3 Laundry circuit.



Bonding shall be provided where necessary to ensure electrical ______________. - ANSWERS-continuity.



and the capacity to conduct safely any fault current likely to be imposed.



2015 IRC Section E3609.1 General



Switches shall not be more than _________________ feet _________________ inches above the floor
or working platform when the switch is in its highest position. - ANSWERS-6 feet



7 inches



Also applies to circuit breakers used as switches.



2015 IRC Section E4001.6 Access.



the rating of any one cord-and-plug- connected utilization equipment shall not exceed ________
percent of the branch-circuit ampere rating. - ANSWERS-80 percent.




2015 IRC Section E3702.3 Fifteen-and 20-ampere branch circuits.

Escuela, estudio y materia

Institución
IRC
Grado
IRC

Información del documento

Subido en
29 de junio de 2026
Número de páginas
27
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$24.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
Tutordanty01

Conoce al vendedor

Seller avatar
Tutordanty01 Chamberlian School of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
-
Miembro desde
5 días
Número de seguidores
0
Documentos
89
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes