Question 1
Which sterilization method is most appropriate for heat-
sensitive, moisture-sensitive instruments such as powered
drills?
A. Steam sterilization (autoclave)
B. Dry heat sterilization
C. Hydrogen peroxide plasma sterilization
D. Boiling water disinfection
Rationale:
Hydrogen peroxide plasma sterilization operates at low
temperatures and leaves no toxic residue, making it ideal for
delicate, heat- and moisture-sensitive devices. Steam and dry
heat methods require high temperatures that would damage
such equipment.
Question 2
,What is the primary purpose of enzymatic detergents in
instrument cleaning?
A. To disinfect instruments immediately
B. To neutralize pH of water
C. To sterilize instruments chemically
D. To break down organic matter such as blood and proteins
Rationale:
Enzymatic detergents contain protease, lipase, and amylase
enzymes that digest organic debris, improving cleaning
efficiency before sterilization. They are not disinfectants or
sterilants.
Question 3
Which of the following best describes the term “bioburden”?
A. Residual chemical on instruments
B. Microbial resistance level
C. Microbial load present on an object before sterilization
D. Heat tolerance of surgical instruments
Rationale:
Bioburden refers to the number of viable microorganisms on
an item prior to sterilization. It directly affects sterilization
time and effectiveness.
Question 4
What is the correct order of instrument processing?
,A. Sterilization → Cleaning → Decontamination → Packaging
B. Packaging → Cleaning → Sterilization → Decontamination
C. Decontamination → Cleaning → Inspection → Packaging
→ Sterilization
D. Cleaning → Sterilization → Packaging → Decontamination
Rationale:
Proper workflow begins with decontamination to reduce
contamination risk, followed by cleaning, inspection,
packaging, and finally sterilization.
Question 5
Which indicator provides the MOST reliable proof that
sterilization conditions were met inside a load?
A. External chemical indicator
B. Mechanical indicator
C. Biological indicator
D. Tape indicator
Rationale:
Biological indicators contain highly resistant spores and
confirm actual microbial kill, making them the gold standard
for sterility assurance.
Question 6
What is the primary function of ultrasonic cleaners?
A. Sterilize surgical instruments
B. Disinfect endoscopes
, C. Remove debris using cavitation bubbles
D. Dry instruments after washing
Rationale:
Ultrasonic cleaners use high-frequency sound waves to create
cavitation bubbles that dislodge debris from intricate
instrument surfaces.
Question 7
Which item would require immediate reprocessing if
packaging is found to be torn?
A. Only sterilization cycle
B. Drying only
C. Full reprocessing starting from cleaning
D. Chemical disinfection only
Rationale:
Any break in packaging compromises sterility, requiring
complete reprocessing beginning with cleaning to ensure
patient safety.
Question 8
Which sterilization parameter is NOT typically used in steam
sterilization validation?
A. Temperature
B. Pressure
C. Exposure time
D. Radiation dose