assuming all other conditions remain constant, a decrease in evaporator load causes - Answer low suction pressure in a flooded evaporator using an accumulator and float valve, flash gas - Answer passes directly into the suction line the oil trap on a refrigeration system is on the - Answer discharge line, as close to the compressor as allowed what controls the operation of a high-side float? - Answer the condenser, and receiver when suction pressure decreases,compressor capacity - Answer decreases cooling-tower water should be maintained at a p h near - Answer 7.8 the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased - Answer refrigeration effect sub cooling the liquid refrigerant just before the expansion valve, results in an increase in - Answer refrigeration effect what percent of oil travels with the refrigerant? - Answer 10 percent any water present in the refrigerant side of a freon refrigeration system causes a - Answer frozen expansion valve when heated, R-12 changes to - Answer phosgene gas in an absorption system, the medium normally used to vaporize refrigerant and increase its temperature is - Answer steam which does not increase the capacity of a water-cooled condenser? - Answer decreasing the ambient temperature

Vista previa del contenido

CIRO: Written Exam Review Practice
test 1 and 2 Questions and Answers.
assuming all other conditions remain constant, a decrease in evaporator load causes - Answer
low suction pressure



in a flooded evaporator using an accumulator and float valve, flash gas - Answer passes
directly into the suction line



the oil trap on a refrigeration system is on the - Answer discharge line, as close to the
compressor as allowed



what controls the operation of a high-side float? - Answer the condenser, and receiver



when suction pressure decreases,compressor capacity - Answer decreases



cooling-tower water should be maintained at a p h near - Answer 7.8



the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased -
Answer refrigeration effect



sub cooling the liquid refrigerant just before the expansion valve, results in an increase in -
Answer refrigeration effect



what percent of oil travels with the refrigerant? - Answer 10 percent



any water present in the refrigerant side of a freon refrigeration system causes a - Answer
frozen expansion valve



when heated, R-12 changes to - Answer phosgene gas



in an absorption system, the medium normally used to vaporize refrigerant and increase its
temperature is - Answer steam



which does not increase the capacity of a water-cooled condenser? - Answer decreasing the
ambient temperature

, when energizing a solenoid valve, to close the valve, its position would normally be - Answer
normally open



a valve that does not restrict flow is the - Answer solenoid valve



the oil separator is located on the - Answer discharge line, as far from the compressor as
possible



when we say a refrigerant is anhydrous, we mean - Answer water is absent



the primary purpose of a purger, in a freon system is the removal of - Answer
noncondensables



operating a freon air-conditioning unit with the filters clogged, is likely to result in - Answer
low suction pressure



a refrigerant overcharge would - Answer increase head pressure



on the most common three-phase, four-wire service, the voltage between any phase and
neutral should be - Answer 120 volts



the following statement about brine is true - Answer p h should be slightly alkaline at 7.8



which desiccant is not used in refrigeration? - Answer soda lime



in an efficiently operating induced-draft cooling tower, the leaving water temperature is -
Answer between dry-bulb, and wet-bulb temperature



which does not remove acid from refrigerant - Answer calcium chloride



which desiccant cannot be used with an R-40 system - Answer calcium chloride



calcium chloride cannot be used with an R-40 system, and will not remove acid from refrigerant
- Answer



the substance commonly used to dry methyl chloride refrigerant is - Answer activated
alumina

Información del documento

Subido en
22 de junio de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
COCOSOLUTIONS
4.2
(37)
Vendido
218
Seguidores
16
Artículos
9130
Última venta
2 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes