ASNT ULTRASONIC LEVEL I EXAM QUESTIONS
WITH DETAILED VERIFIED ANSWERS
The indication on the instrument display that represents the far boundary of the
| | | | | | | | | | | | |
material being tested. - CORRECT ANSWER✔✔-Far boundary indication
| | | | | | |
The position of the transducer is often varied to transmit sound into the test part
| | | | | | | | | | | | | | |
at various angles to the front surface. - CORRECT ANSWER✔✔-Immersion testing
| | | | | | | | | |
The cable that connects the ultrasonic instrument to the transducer is specially
| | | | | | | | | | | |
designed so that one conductor is centered inside another. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Coaxial cable |
The process of comparing an instrument or device with a standard. - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Calibration
Another name for a longitudinal wave. - CORRECT ANSWER✔✔-Compressional
| | | | | | | | |
wave
Another name for surface waves. - CORRECT ANSWER✔✔-Rayleigh wave
| | | | | | | |
A material used between the face of a transducer and the test surface to permit
| | | | | | | | | | | | | | |
or improve the transmission of ultrasonic vibrations. - CORRECT ANSWER✔✔-
| | | | | | | | |
Couplant
,The material in a transducer that vibrates to produce ultrasonic waves. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-Piezoelectric material
| |
Testing of material where the transducer is in direct contact with the material
| | | | | | | | | | | | |
being tested. - CORRECT ANSWER✔✔-Ultrasonic testing
| | | | |
An advantage of using lithium sulfate in transducers is that it is one of the most
| | | | | | | | | | | | | | | |
efficient generators of ultrasonic energy. - CORRECT ANSWER✔✔-Lithium sulfate
| | | | | | | |
The transducer that contains the thinnest piezoelectric crystal is a 25 MHz
| | | | | | | | | | | |
transducer. - CORRECT ANSWER✔✔-Transducer frequency
| | | |
The amount of beam divergence from a crystal is primarily dependent on the
| | | | | | | | | | | | |
frequency and crystal size. - CORRECT ANSWER✔✔-Beam divergence
| | | | | | |
When an ultrasonic beam passes through the interface between two dissimilar
| | | | | | | | | | |
materials at an angle, a new angle of sound travel takes place in the second
| | | | | | | | | | | | | | |
material. - CORRECT ANSWER✔✔-Refraction
| | |
Represents the initial pulse or front surface indication in Figure 2. - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Indication A |
Represents the first discontinuity indication in Figure 2. - CORRECT ANSWER✔✔-
| | | | | | | | | |
Indication B |
, Represents the second back surface reflection in Figure 2. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Indication C |
Represents the second indication of the discontinuity in Figure 2. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-Indication D |
Represents the second back surface reflection in Figure 2. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Indication E |
Approximately _________ the velocity of shear waves in the same material. -
| | | | | | | | | | | |
CORRECT ANSWER✔✔-Velocity of surface waves
| | | |
The first front surface indication. - CORRECT ANSWER✔✔-Indication A
| | | | | | | |
First back surface reflection. - CORRECT ANSWER✔✔-Indication B
| | | | | | |
First discontinuity reflection. - CORRECT ANSWER✔✔-Indication C
| | | | | |
Second discontinuity indication. - CORRECT ANSWER✔✔-Indication D
| | | | | |
The distance from the front surface of the aluminum block to the discontinuity. -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Distance between indications A and B
| | | | | |
5 MHz. - CORRECT ANSWER✔✔-Best resolving power frequency
| | | | | | |
WITH DETAILED VERIFIED ANSWERS
The indication on the instrument display that represents the far boundary of the
| | | | | | | | | | | | |
material being tested. - CORRECT ANSWER✔✔-Far boundary indication
| | | | | | |
The position of the transducer is often varied to transmit sound into the test part
| | | | | | | | | | | | | | |
at various angles to the front surface. - CORRECT ANSWER✔✔-Immersion testing
| | | | | | | | | |
The cable that connects the ultrasonic instrument to the transducer is specially
| | | | | | | | | | | |
designed so that one conductor is centered inside another. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Coaxial cable |
The process of comparing an instrument or device with a standard. - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Calibration
Another name for a longitudinal wave. - CORRECT ANSWER✔✔-Compressional
| | | | | | | | |
wave
Another name for surface waves. - CORRECT ANSWER✔✔-Rayleigh wave
| | | | | | | |
A material used between the face of a transducer and the test surface to permit
| | | | | | | | | | | | | | |
or improve the transmission of ultrasonic vibrations. - CORRECT ANSWER✔✔-
| | | | | | | | |
Couplant
,The material in a transducer that vibrates to produce ultrasonic waves. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-Piezoelectric material
| |
Testing of material where the transducer is in direct contact with the material
| | | | | | | | | | | | |
being tested. - CORRECT ANSWER✔✔-Ultrasonic testing
| | | | |
An advantage of using lithium sulfate in transducers is that it is one of the most
| | | | | | | | | | | | | | | |
efficient generators of ultrasonic energy. - CORRECT ANSWER✔✔-Lithium sulfate
| | | | | | | |
The transducer that contains the thinnest piezoelectric crystal is a 25 MHz
| | | | | | | | | | | |
transducer. - CORRECT ANSWER✔✔-Transducer frequency
| | | |
The amount of beam divergence from a crystal is primarily dependent on the
| | | | | | | | | | | | |
frequency and crystal size. - CORRECT ANSWER✔✔-Beam divergence
| | | | | | |
When an ultrasonic beam passes through the interface between two dissimilar
| | | | | | | | | | |
materials at an angle, a new angle of sound travel takes place in the second
| | | | | | | | | | | | | | |
material. - CORRECT ANSWER✔✔-Refraction
| | |
Represents the initial pulse or front surface indication in Figure 2. - CORRECT
| | | | | | | | | | | | |
ANSWER✔✔-Indication A |
Represents the first discontinuity indication in Figure 2. - CORRECT ANSWER✔✔-
| | | | | | | | | |
Indication B |
, Represents the second back surface reflection in Figure 2. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Indication C |
Represents the second indication of the discontinuity in Figure 2. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-Indication D |
Represents the second back surface reflection in Figure 2. - CORRECT
| | | | | | | | | | |
ANSWER✔✔-Indication E |
Approximately _________ the velocity of shear waves in the same material. -
| | | | | | | | | | | |
CORRECT ANSWER✔✔-Velocity of surface waves
| | | |
The first front surface indication. - CORRECT ANSWER✔✔-Indication A
| | | | | | | |
First back surface reflection. - CORRECT ANSWER✔✔-Indication B
| | | | | | |
First discontinuity reflection. - CORRECT ANSWER✔✔-Indication C
| | | | | |
Second discontinuity indication. - CORRECT ANSWER✔✔-Indication D
| | | | | |
The distance from the front surface of the aluminum block to the discontinuity. -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-Distance between indications A and B
| | | | | |
5 MHz. - CORRECT ANSWER✔✔-Best resolving power frequency
| | | | | | |