◉ The changes in kilovoltage (kVp) will result in the greatest
reduction of patient dose, when milliampere-seconds (mAs) is
adjusted to compensate for the change.
Answer: Increase kVp by 30%


◉ The following image receptor (IR) system speeds will result in the
lowest patient dose.
Answer: Faster speed IR system


◉ The primary purpose of using gonad shields.
Answer: reduce the likelihood of genetic effects


◉ Are gonad shields.
Answer: Contact and shadow


◉ gonad shielding should be used.
Answer: when the gonads are within 5 cm of the radiation field

,◉ the greatest cause of unnecessary radiation to patients that can be
controlled by the limited operator is.
Answer: repeat exposures


◉ the limited operator can reduce repeat exposure.
Answer: clearly instructing patients


◉ how does the x-ray beam restriction minimize patient exposure.
Answer: it limits the radiation field to the area of interest


◉ what is the device that allows the limited operator to vary the size
of the radiation field.
Answer: collimator


◉ how does filtration reduce patient exposure.
Answer: removes longer-wavelength photons


◉ The National Council on Radiation Protection and
Measurements(NCRP) recommendation for the amount of total
filtration.
Answer: 2.5 mm Al equiv

,◉ Three principal methods used to protect limited operators from
unnecessary radiation exposure.
Answer: time, distance, and shielding


◉ The following is not a type of personal radiation shielding.
Answer: Shadow


◉ personnel shielding must be worn on the rare occasion during
which the limited operator may need to remain in the radiographic
room during an exposure to assist the patient in maintaining the
proper position. What is the source of the greatest radiation hazard
under this circumstance.?.
Answer: scattered radiation from the patient


◉ the term for radiation the escapes from the x-ray tube housing.
Answer: leakage radiation


◉ why are limited operators prohibited from activities that result in
direct exposure to the primary x-ray beam.
Answer: they are considered occupationally exposed individuals


◉ distance, as a method used to limit operator exposure, means that.
Answer: the operator should maximize the distance from the source
during an exposure

, ◉ shielding worn for personnel protection is designed to attenuate
what source of exposure.
Answer: scatter radiation


◉ the acronym for a common type of personnel dosimeter.
Answer: TLD


◉ What is the recommended placement for personnel dosimeter on
the body of the limited operator.
Answer: the badge should be worn in the region of the collar on the
anterior surface of the body and outside the lead apron, if worn


◉ The NCRP recommended annual effective dose limit for
occupational exposure.
Answer: 5.0 rem (0.05 Sv)


◉ The NCRP recommended monthly effective (or equivalent) dose
limit to the fetus for a pregnant worker.
Answer: 0.05 rem (0.0005 Sv)


◉ Radiation monitoring of personnel is required when what
percentage of the annual occupational effective dose limit is likely to
be received.

Información del documento

Subido en
18 de junio de 2026
Número de páginas
40
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
FocusFile7
3.9
(23)
Vendido
220
Seguidores
3
Artículos
54806
Última venta
3 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes