1. Which material is commonly approved for residential water distribution
piping?
A. Galvanized steel
B. PVC Schedule 40 for hot water
C. Copper Type L
D. Lead pipe
Answer: C – Copper Type L ✔
*Rationale: Copper Type L is widely accepted under the International Plumbing
Code (IPC) for residential water distribution due to its durability and corrosion
resistance.
2. What is the minimum slope required for a 3-inch horizontal drainage pipe?
A. 1/4 inch per foot
B. 1/8 inch per foot
C. 1/16 inch per foot
D. 1 inch per foot
,Answer: A – 1/4 inch per foot ✔
*Rationale: The IPC requires a minimum slope of 1/4 inch per foot for pipes 3
inches and smaller to ensure proper gravity drainage.
3. A trap is primarily designed to:
A. Increase water pressure
B. Prevent sewer gases from entering the building
C. Filter solids from wastewater
D. Increase flow velocity
Answer: B – Prevent sewer gases from entering the building ✔
*Rationale: A trap maintains a water seal that blocks sewer gases while allowing
wastewater to pass.
4. Which fixture requires a vent?
A. Only toilets
B. Only kitchen sinks
C. All plumbing fixtures connected to a drainage system
D. Only floor drains
Answer: C – All plumbing fixtures connected to a drainage system ✔
*Rationale: Venting is required to maintain neutral air pressure in all fixture
drains.
5. The primary purpose of a plumbing vent system is to:
A. Remove wastewater
B. Supply water to fixtures
C. Equalize air pressure in drainage piping
D. Increase water velocity
,Answer: C – Equalize air pressure in drainage piping ✔
*Rationale: Vent systems prevent siphonage and backpressure in drainage pipes.
6. Which of the following is NOT a sanitary drainage fitting?
A. Wye
B. Sanitary tee
C. Cross fitting
D. Double check valve
Answer: D – Double check valve ✔
*Rationale: A double check valve is a backflow prevention device, not a drainage
fitting.
7. The minimum diameter for a residential toilet drain is typically:
A. 1 1/2 inches
B. 2 inches
C. 3 inches
D. 4 inches
Answer: C – 3 inches ✔
*Rationale: The IPC generally requires a minimum 3-inch drain line for water
closets.
8. A water hammer arrestor is used to:
A. Increase water pressure
B. Prevent pipe freezing
C. Absorb shock from sudden valve closure
D. Filter debris
, Answer: C – Absorb shock from sudden valve closure ✔
*Rationale: Water hammer arrestors reduce pressure surges caused by rapid
valve closure.
9. Which pipe material is prohibited in new potable water systems in most U.S.
codes?
A. Copper
B. PEX
C. Lead
D. CPVC
Answer: C – Lead ✔
*Rationale: Lead pipes are prohibited due to health hazards and toxicity.
10. A cleanout is required:
A. At every fixture
B. Only at roof vents
C. At strategic points for drainage system access
D. Only at traps
Answer: C – At strategic points for drainage system access ✔
*Rationale: Cleanouts allow maintenance and removal of blockages in drainage
systems.
11. The minimum air gap between a faucet and flood rim is:
A. 1 inch
B. Equal to pipe diameter
C. Twice pipe diameter
D. No requirement