MEDICAL GAS 6010 INSTALLERS PRACTICE
TEST FOR ASSE 6010 CERTFICATION PREP
EXAM WITH ACTUAL CORRECT QUESTIONS
AND VERIFIED DETAILED
ANSWERS|CURRENTLY TESTING
VERSION|ALREADY GRADED A+|EXPERT
VERIFIED FOR GUARANTEED PASS 2026|

A master alarm panel shall be located in the office or work space of the individual responsible
for the maintenance of the medical gas piping system. The other master alarm shall be located
in _ ?

A) an area of continuous observation

B) the nurse station

C) the office of the authority having jurisdiction

D) the source equipment room

A) an area of continuous observation

A master alarm system shall consist of two or more alarm panels, one of which can be
substituted by a _ ?

A) area alarm

B) centralized computer system

C) fire alarm

D) security system

B) centralized computer system

Where an initiating device is remote from the building a _ set of wires shall be permitted to
connect the initiating device to a junction box where the wiring first enters the building?

A) double

B) duplex

1|Page

,C) single

D) triple

C) single

Two master alarm panels shall be wired independently to the initiating device for each signal,
and a single initiating device shall be permitted to actuate _ ?

A) a computer

B) a single master alarm panel

C) area alarm panels

D) multiple master alarms panels

D) multiple master alarms panels

When a medical gas system is supplied by a manifold or other alternating-type bulk system, the
_ alarm system shall activate when, or just before, changeover occurs?

A) area

B) local

C) master

D) security

C) master



The master alarm system shall activate when the main line of the medical-surgical vacuum
system drops to or below _ in. HgV?

A) 10

B) 12

C) 30

D) 32

C) 12

A signal from each local alarm system shall be connected to the _ alarm panels to indicate that a
problem is present with the source equipment?


2|Page

,A) area

B) fire

C) master

D) warning

C) master

The medical air dew point high alarm from each compressor site will indicate at the master
alarm panels when the line pressure dew point is greater that _ *F?

A) +22

B) +32

C) +35

D) +44

C) +35

The instrument air dew point high alarm from each compressor site will indicate at the master
alarm panels when the line pressure dew point is greater than _ *F?

A) -22

B) -32

C) -35

D) -44

A) -22

Area alarm panels for medical gas systems shall indicate when line pressure in the area being
monitored increases or decreases _ % from normal operating pressure?

A) 10

B) 15

C) 20

D) 25

C) 20



3|Page

, In positive pressure systems area alarm sensors for vital life support and critical care areas shall
be located on which side of the zone valve box assemblies?

A) main line side

B) patient or use side

C) source side

D) upstream side

B) patient or use side

Areas for anesthetizing gas delivery shall have area alarm pressure sensors installed on the _
side of the individual room zone valve box assembly?

A) in

B) patient

C) source

D) source or patient

D) source or patient

If there is more than one source equipment location in a facility, it shall be necessary for each
location to have separate alarms at the _ panels?

A) area

B) fire

C) master

D) security

C) master

High carbon monoxide levels in a medical air system shall be indicated at each local alarm. The
alarm shall activate at _ ppm or higher?

A) 10

B) 20

C) 100

D) 1000


4|Page

Información del documento

Subido en
13 de junio de 2026
Número de páginas
35
Escrito en
2022/2023
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Drgary
4.6
(1402)
Vendido
532
Seguidores
217
Artículos
3285
Última venta
1 día hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes