Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

NCLE Practice Test ACTUAL UPDATED QUESTIONS AND CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
13-06-2026
Escrito en
2025/2026

NCLE Practice Test ACTUAL UPDATED QUESTIONS AND CORRECT ANSWERS

Institución
ABO
Grado
ABO

Vista previa del contenido

NCLE Practice Test ACTUAL UPDATED QUESTIONS AND CORRECT ANSWERS

A Correct Statement regarding epithelial cells is that they: d) have the ability to reproduce


a) Comprise the posterior layer of the cornea
b) Are unable to regenerate
c) Comprise the thickest layer of the cornea
d) Have the ability to reproduce



Which of the following prescriptions indicates against- a)-4.50 +1.00 x75
the-rule astigmatism?


a)-4.50 +1.00 x75
b)-4.50 +1.00 x 180
c)-4.50 -1.00 x 165
d)4.50 -1.00 x 180


When a keratometer is being calibrated, which of the c) a set of steel balls of known radii
following targets will provide the most reliable result?


a) the single-cut anterior surface of a high-plus lens
b) a perfectly flat highly polished mirror
c) a set of steell balls of known radii
d) the unfinished posterior surface of a low-minus lens

,Inadequate movement of a soft lens can be corrected by b)has a smaller diameter
using a lens that


a) has a steeper base curve
b) has a smaller diameter
c) has a larger diameter
d) has a higher water content


A long-term, successful, hydrogel contact lens wearer c) use of anti-histamines
suddenly develops dry eyes. Which of the following is
most likely to cause this problem?


a) Use of oxidative solution
b) use of rewetting drops
c) use of anti-histamines
d) Wearing of lenses in the wrong eyes


During slit-lamp evaluation, on upward gaze, a patient's a) a good fit
soft contact lenses move 0.5 to 1mm when the patient
blinks. These lenses are:


a) a good fit
b) too loose
c) too tight
d) too large


A new daily wearer of soft lenses returns for the first a) solution reaction
follow up visit with itching, burning, injected eyes. The
most likely cause of these problems is:


a) solution reaction
b) giant-cell papillary conjunctivitis
c) a lens fit that is too loose
d) inability to wear soft lenses


Which of the following is the mode of slit-lamp a) Retroillumination
illumination used to view the early stages of microcystic
edema?


a) Retroillumination
b) Direct illumination
c) Parrallelpiped
d) Oscillation


Which of the following changes is best able to improve b) Increasing Dk
oxygen transmissibility to a patient's cornea?


a) Increasing tear exchange
b) Increasing Dk
c) Increasing optical zone diameter
d) Increasing CN bevel

, In using fluorescein to evaluate the fit of a rigid lens of d) apical area, mid-peripheral area, and the lens edges should be assessed
9.0mm diameter on a typical eye, a correct statement is
that:


a) apical touch with pooling in the PPC curve area is
preferred
b) apical toxicity may not be obvious
c) apical pooling with edge touch is recommended
d) apical area, mid-peripheral area, and the lens edges
should be assessed


Which of the following changes would improve a rigid b) Reduce overall diameter
contact lens fit that shows sluggish movement after 1 hour
of wear?


a) Add hyperflange edge treatment
b) Reduce overall diameter
c) Decrease center thickness
d) Increase overall diameter


Moving a +7.50 RX from the spectacle plane to the c) more plus power
corneal plane will require:


a) no change in power
b) more minus power
c) more plus power
d) less plus power


A fluorescein pattern that has a black area over the a) flat fit
corneal apex and a diffuse green area in the periphery
normally indicates:


a) flat fit
b) steep fit
c) normal fit
d) tight fit


IPC's are used to: a) provide a transition between the peripheral and base curves


a) provide a transition between the peripheral and base
curves
b) reduce edge thickness and lens mass
c) increase the optical zone
d) smooth the lens edge


A toric soft lens with an RX of -2.00 -1.25 x 120 has the axis a) 90 degrees
resting at the 5 o' clock position. What should the new
axis be when the lens is ordered?


a) 90 degrees
b) 105 degrees
c) 135 degrees
d) 150 degrees

Escuela, estudio y materia

Institución
ABO
Grado
ABO

Información del documento

Subido en
13 de junio de 2026
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$17.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Briwisescore Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
20
Miembro desde
2 año
Número de seguidores
5
Documentos
9901
Última venta
4 semanas hace

1.7

3 reseñas

5
0
4
0
3
1
2
0
1
2

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes